31 / 99 page ![]() January 25, 2005 S29WS-N_00_G0 29 Ad vance Information A hardware reset immediately terminates the program operation. The program command sequence should be reinitiated once the device has returned to the read mode, to ensure data integrity. Figure 7.3. Single Word Program Write Unlock Cycles: Address 555h, Data AAh Address 2AAh, Data 55h Write Program Command: Address 555h, Data A0h Program Data to Address: PA, PD Unlock Cycle 1 Unlock Cycle 2 Setup Command Program Address (PA), Program Data (PD) FAIL. Issue reset command to return to read array mode. Perform Polling Algorithm (see Write Operation Status flowchart) Yes Yes No No Polling Status = Busy? Polling Status = Done? Error condition (Exceeded Timing Limits) PASS. Device is in read mode. |
|
Link URL |
| Does ALLDATASHEET help your business so far? [ DONATE ] |
About Alldatasheet | Advertisement | Contact us | Privacy Policy | Link to Datasheet | Link Exchange | Manufacturer List All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|