Electronic Components Datasheet Search
  English  ▼

X  

S29WS064N0LBAI011 Datasheet(PDF) 57 Page - SPANSION

Part # S29WS064N0LBAI011
Description  256/128/64 MEGABIT CMOS 1.8 VOLT ONLY SIMULTANEOUS READ/WRITE BURST MODE FLASH MEMORY
PDF  99 Pages
Scroll/Zoom Zoom In 100%  Zoom Out
Manufacturer  SPANSION [SPANSION]
Direct Link  http://www.spansion.com
Logo SPANSION - SPANSION

S29WS064N0LBAI011 Datasheet(HTML) 57 Page - SPANSION

Back Button S29WS064N0LBAI011 Datasheet HTML 53Page - SPANSION S29WS064N0LBAI011 Datasheet HTML 54Page - SPANSION S29WS064N0LBAI011 Datasheet HTML 55Page - SPANSION S29WS064N0LBAI011 Datasheet HTML 56Page - SPANSION S29WS064N0LBAI011 Datasheet HTML 57Page - SPANSION S29WS064N0LBAI011 Datasheet HTML 58Page - SPANSION S29WS064N0LBAI011 Datasheet HTML 59Page - SPANSION S29WS064N0LBAI011 Datasheet HTML 60Page - SPANSION S29WS064N0LBAI011 Datasheet HTML 61Page - SPANSION Next Button
Zoom Inzoom in Zoom Outzoom out
 57 / 99 page
background image
January 25, 2005 S29WS-N_00_G0
55
Ad vance
Information
10. The Password Unlock command cannot be issued any faster than 1 µs at a time to pre-
vent a hacker from running through all the 64-bit combinations in an attempt to
correctly match a password.
11. Approximately 1 µs is required for unlocking the device after the valid 64-bit password
is given to the device.
12. Password verification is only allowed during the password programming operation.
13. All further commands to the password region are disabled and all operations are
ignored.
14. If the password is lost after setting the Password Mode Lock Bit, there is no way to clear
the PPB Lock Bit.
15. Entry command sequence must be issued prior to any of any operation and it disables
reads and writes for Bank 0. Reads and writes for other banks excluding Bank 0 are
allowed.
16. If the user attempts to program or erase a protected sector, the device ignores the com-
mand and returns to read mode.
17. A program or erase command to a protected sector enables status polling and returns
to read mode without having modified the contents of the protected sector.
18. The programming of the DYB, PPB, and PPB Lock for a given sector can be verified by
writing individual status read commands DYB Status, PPB Status, and PPB Lock Status
to the device.



Html Pages

1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55 56 57 58 59 60 61 62 63 64 65 66 67 68 69 70 71 72 73 74 75 76 77 78 79 80 81 82 83 84 85 86 87 88 89 90 91 92 93 94 95 96 97 98 99


Datasheet Download

Go To PDF Page


Link URL



Does ALLDATASHEET help your business so far?  [ DONATE ] 

About Alldatasheet   |   Advertisement   |   Contact us   |   Privacy Policy   |   Link to Datasheet    |   Link Exchange   |   Manufacturer List
All Rights Reserved©Alldatasheet.com


Mirror Sites
English : Alldatasheet.com  |   English : Alldatasheet.net  |   Chinese : Alldatasheetcn.com  |   German : Alldatasheetde.com  |   Japanese : Alldatasheet.jp
Russian : Alldatasheetru.com  |   Korean : Alldatasheet.co.kr  |   Spanish : Alldatasheet.es  |   French : Alldatasheet.fr  |   Italian : Alldatasheetit.com
Portuguese : Alldatasheetpt.com  |   Polish : Alldatasheet.pl  |   Vietnamese : Alldatasheet.vn
Indian : Alldatasheet.in  |   Mexican : Alldatasheet.com.mx  |   British : Alldatasheet.co.uk  |   New Zealand : Alldatasheet.co.nz
Family Site : ic2ic.com  |   icmetro.com