38 / 83 page ![]() © GRAYCHIP,INC. - 33 - August 27, 2001 GC4016 MULTI-STANDARD QUAD DDC CHIP DATA SHEET REV 1.0 This document contains information which may be changed at any time without notice ADDRESS 4: General Sync Register, Suggested default = 0x27, Cleared by power up ADDRESS 5: Count Sync Register, Suggested default = 0x50 ADDRESS 6: Counter Byte 0, Suggested default = DEC (CIC decimation value) ADDRESS 7: Counter Byte 1, Suggested default = DEC The chip’s internal sync counter counts in cycles of 256(CNT+1) clocks. A terminal count signal (TC) is output at the end of each cycle. The counter can be synchronized to an external sync as specified in the Count Sync Register (address 5). If CNT is set so that 256(CNT+1) is a multiple of sixteen times the CIC decimation ratio (i.e., a multiple of 16N), then the terminal count of this counter can be output on the SO pin and used to periodically synchronize multiple GC4016 chips. BIT TYPE NAME DESCRIPTION 0-2 (LSB) R/W DIAG_SYNC The Checksum generator is strobed by this sync. See Table 7 for the possible sync selections. 3-5 R/W OUTPUT_SYNC The selected sync is inverted and output on the SO pin. See Table 7. 6 R/W 4_BIT_ADDRESS This mode allows four address bits (such as the expansion bus of the TI320C6202) instead of 5 to be used. In this mode each page contains 8 words (rather than 16). The LSB of the page register is used as address bit A3. Pin A3 should be grounded in this mode. 7 (MSB) R/W DIFF_IN Enables differential receivers. Both this bit and the corresponding bits in each channel must be set to properly receive differential signals. This bit should be cleared for other inputs and for minimum power consumption. Contact Graychip for the use of the differential input mode. BIT TYPE NAME DESCRIPTION 0-1 LSB R/W DIAG_SOURCE This two bit field selects the diagnostic input source used when the INPUT_SEL field in each channel’s control register is set to 6 or 7 (See channel control address 27). DIAG_SOURCE = 0 selects the 16 LSB’s of the counter (see addresses 6&7) as a diagnostic ramp. DIAG_SOURCE=1 is a zero input, DIAG_SOURCE=2 is unused, DIAG_SOURCE= 3 gives a 0x4000 constant input. 2-4 R/W COUNTER_SYNC Synchronizes the sync counter. This counter is used to generate the periodic TC sync. See Table 7. 5 R/W COUNT_TEST Used during factory tests. Should be set to 0 for normal operation. 6 R/W OS_MODE The ONE_SHOT signal is a level, not a pulse when this bit is set. 7 (MSB) R/W ONE_SHOT The one shot sync signal (OS) is generated when this bit is set. If OS_MODE is low, then a one shot pulse (one clock cycle wide) is generated. If OS_MODE is high, then the ONE_SHOT sync is active while this bit is high. This bit must be cleared before another one shot pulse can be generated. BIT TYPE NAME DESCRIPTION 0-7 R/W CNT[0:7] The LSBs of the counter cycle period BIT TYPE NAME DESCRIPTION 0-7 R/W CNT[8:15] The 8 MSBs of the counter cycle period |
|
Link URL |
| Does ALLDATASHEET help your business so far? [ DONATE ] |
About Alldatasheet | Advertisement | Contact us | Privacy Policy | Link to Datasheet | Link Exchange | Manufacturer List All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |