| Electronic Components Datasheet Search |
|
GC4016 Datasheet(PDF) 29 Page - Texas Instruments |
|
|
|||||||||||||||||||||||||||||
GC4016 Datasheet(HTML) 29 Page - Texas Instruments |
|
29 / 83 page ![]() © GRAYCHIP,INC. - 24 - August 27, 2001 GC4016 MULTI-STANDARD QUAD DDC CHIP DATA SHEET REV 1.0 This document contains information which may be changed at any time without notice 3.10 POWER DOWN MODES The chip has a power down and clock loss detect circuit. This circuit detects if the clock is absent long enough to cause dynamic storage nodes to lose state. If clock loss is detected, an internal reset state is entered to force the dynamic nodes to become static. The control registers are not reset and will retain their values, but any data values within the chip will be lost. When the clock returns to normal the chip will automatically return to normal. In the reset state the chip consumes only a small amount of standby power. The user can select whether this circuit is in the automatic clock-loss detect mode, is always on (power down mode), or is disabled (the clock reset never kicks in) using the CK_LOSS_DETECT and GLOBAL_RESET control bits in address 0. The whole chip, or individual down converter channels can be powered down. NOTE: Resampler channel 0 provides the “block complete” signal to the output FIFO when OUTPUT_ORDER=1 or 2. This means that the channel feeding resampler channel 0, typically channel A (see CHAN_MAP in the resampler control page), can not be powered down when OUTPUT_ORDER=1 or 2. 3.11 SYNCHRONIZATION Each GC4016 chip can be synchronized through the use of one of two sync input signals, an internal one shot sync generator, or a sync counter. The sync to each circuit can also be set to be always on or always off. Each circuit within the chip, such as the sine/cosine generators or the decimation control counter can be synchronized to one of these sources. These syncs can also be output from the chip so that multiple chips can be synchronized to the syncs coming from a designated “master” GC4016 chip. The 3 bit sync mode control for each sync circuit is defined in Table 7: NOTE: the internal syncs are active high. The SIA and SIB inputs have been inverted to be the active high syncs SIA and SIB in Table 7. The ONE_SHOT can either be a level or a pulse as selected by the OS_MODE control bit. The level mode is used to initialize the chip, the pulse mode is used to synchronously switch frequency, phase or gain values. Typically the decimation counters (DEC_SYNC), the flush circuits (FLUSH_SYNC) and the output block sync (OUT_BLK_SYNC) will be set to SIA, while the NCO phase accumulator syncs (NCO_SYNC) will be set to SIB. The SIA input can then be used to initialize and flush the channels and the SIB sync input can be used, if desired, to synchronize the phases of the NCOs. The recommended sync mode settings are summarized in Table 8. The SIA and SIB sync inputs are either connected to a user defined sync generator, for example, an FPGA, or are tied to a GC4016 chip’s sync output pin (SO). If there are multiple GC4016 chips in the system, then the SO pin of one chip can be used to drive the SIA input of all chips, and the SO pin of another chip can drive the SIB inputs of all chips. Table 7: Sync Modes MODE SYNC SOURCE 0,1 off (never asserted) 2 SIA 3 SIB 4 ONE_SHOT 5 TC (terminal count of internal counter) 6,7 on (always active) Table 8: Recommended Sync Settings Global Syncs (Addresses 4 and 5) Channel Syncs (Pages 7, 15, 23 and 31) Sync Value Description Sync Value Description DIAG_SYNC 7 (always) Only used during diagnostics PHASE_SYNC 7 (always) Use phase settings as they are loaded OUTPUT_SYNC 4 (OS) The SO output is used during initialization FREQ_SYNC 7 (always) Use frequency settings as they are loaded COUNTER_SYNC 4 (OS) Sync counter with one shot pulse NCO_SYNC 2 (SIA) Sync the phase accumulator during initialization. Set to SIB for frequency hopping. Output Circuit Sync (Page 98) DITHER_SYNC 0 (never) or 2 (SIA) Can free run except during diagnostics, or reset during initialization OUT_BLK_SYNC 2 (SIA) Sync the output block during initialization ZPAD_SYNC 2 (SIA) Sync the zero pad circuit during initialization Resampler syncs (Page 64) DEC_SYNC 2 (SIA) Sync the channel decimation during initialization RES_SYNC 2 (SIA) Sync the Resampler during initialization FLUSH_SYNC 2 (SIA) Flush the channels during initialization RATIO_SYNC 7(always) Set to always except when synchronously changing ratios GAIN_SYNC 7 (always) Use fine gain settings as they are loaded PEAK_SYNC 5 (TC) Periodically capture peak count data |
|
Link URL |
| Does ALLDATASHEET help your business so far? [ DONATE ] |
About Alldatasheet | Advertisement | Contact us | Privacy Policy | Link to Datasheet | Link Exchange | Manufacturer List All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |