| Electronic Components Datasheet Search |
|
GC4016 Datasheet(PDF) 22 Page - Texas Instruments |
|
|
|||||||||||||||||||||||||||||
GC4016 Datasheet(HTML) 22 Page - Texas Instruments |
|
22 / 83 page ![]() © GRAYCHIP,INC. - 17 - August 27, 2001 GC4016 MULTI-STANDARD QUAD DDC CHIP DATA SHEET REV 1.0 This document contains information which may be changed at any time without notice reduce the interrupt rate and to let the user read more samples after each interrupt. When the user has finished reading the block of data he sets the READY control bit in the Status Register (address1). When the output FIFO has a new block of data ready, it will clear the READY bit. If a block of data completes and the READY bit is not set, then the chip sets the MISSED control bit. The MISSED bit serves as a diagnostic indicating that the processor was too slow and missed a block of data. Note that the rate at which the blocks are filled, and therefore the rate at which the data needs to be read from the microprocessor port, is dependent upon how fast the resampler can generate new output samples. When the resampler is interpolating, which is the resampler’s most commonly used mode, it will generate multiple output samples each time it receives a sample from a downconverter channel. The user should use the resampler’s clock divider to slow its computation rate if the resampler is generating outputs too fast (See Section 3.5.4). The RDY pin can serve as an interrupt to inform the processor that a new block of samples is ready. The width and polarity of the RDY pulse is programmable (See EN_RDY in address16 and INV_RDY and RDY_WIDTH in address 17). The mapping of the output data into registers 16 through 31 is dependent upon the OUTPUT_ORDER control mode in address 21, the number of active channels, and whether the channels are synchronous or asynchronous. If OUTPUT_ORDER=0 and BLOCK_SIZE=3, then each block will contain the next four samples output from the resampler. If the channels are synchronous, then the block will contain one sample from each channel. If there are only two active channels, then the block will contain two samples from each channel. If there is only one active output channel, then the block will contain four consecutive samples from the active channel. If the channels are asynchronous, or if there are three active channels, then the output block will contain the next four samples computed by the resampler. In this case tags are required to separate the channels. OUTPUT_ORDER=0 must be used for asynchronous data. If OUTPUT_ORDER=1 or 2, then the channels are written into the FIFO using the channel number as part of the address. In this mode the previous block is complete when the Q-half of the output from channel A arrives. If the resampler ratio is the same integral value for all channels, then channels B, C and D can be powered down and back up again while maintaining proper channel ordering. Channel A may not be powered down because it provides the “Block Complete” timing signal. OUTPUT_ORDER settings of 1 and 2 are valid for synchronous channels, but NOT for asynchronous channels. The following tables illustrate how the 24 bit channel outputs are mapped into addresses 16 through 31 of pages 96 and 97. Note that addresses 16, 20, 24 and 28 are the unused LSBs of the 32 bit words and always read back zero. Addresses 19, 23, 27 and 31 contain the MSBs of the output. In the 12,16, or 20 bit output mode, all values are rounded into the MSBs and the unused LSBs are cleared. These tables assume that BLOCK_SIZE = 3 which sets the block size to four complex words. Table 3: Output Mode Controls Control Register Address (Page 98) Suggested Default for Each Mode (hex values) Micro- processor mode Wide Word micro- processor mode Serial modes Nibble mode Link mode Parallel mode Four serial outputs TDM output (synchronous) Asynchro- nous Mode Tristate Controls 16 02 FA 7F 7F1 7F1 7F1 7D FF Output Formats 17 40 40 40 40 40 40 48 40 Output Modes 18 08 08 28 282 282 4A CB 6C Output Frame Controls 19 00 00 01 073 01 07 00 00 Output Word Sizes 20 E8 E8 E9 EF 29 C8 08 E85 Output Clocks 21 00 00 B1 01 01 01 01 01 Serial Mux Controls 22 00 00 E4 E4 E4 00 00 00 Output Tag A 23 10 00 10 Output Tag B 24 32 11 32 Output Tag C 25 45 22 45 Output Tag D 26 67 33 67 Miscellaneous 28 02 034 02 NOTES: 1. For TDM serial or nibble modes the master chip’s value should be 7F, the slaves’ 7D. 2. For TDM serial or nibble modes the master chip’s value should be 28, the slaves’ 20. 3. For multi-chip modes the frame length is set as described in Section 3.8.3. 4. Also set the RND22control bit in address 19 (bit 6) of the resampler control page (page 64). 5. For Asynchronous parallel modes set address 20 to 28. |
|
Link URL |
| Does ALLDATASHEET help your business so far? [ DONATE ] |
About Alldatasheet | Advertisement | Contact us | Privacy Policy | Link to Datasheet | Link Exchange | Manufacturer List All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |