| Electronic Components Datasheet Search |
|
PC8374L Datasheet(PDF) 134 Page - National Semiconductor (TI) |
|
|
|
|||||||||||||||||||||||||||||
PC8374L Datasheet(HTML) 134 Page - National Semiconductor (TI) |
|
134 / 239 page ![]() 8.0 Health Management (HM) (Continued) www.national.com 134 Revision1.1 The FSTLMD bit in the associated Extended FANPWM Control register (see Section 8.5.85 on page 190) selects one of the following two options as the fan condition that enables the detection of a fan failure: ● Either a fan stalled condition or a low speed condition. (This option is recommended for Manual and Constantly On fan control; see “Control Modes” in Section 8.2.8.) ● A fan stalled condition only. (This is recommended for Automatic fan control if SPIN_END bit in associated Extended FANPWM Control register is set to 0; in this case, the setting of the Fan Tachometer Low Limit register indicates the fan speed at which the spin-up is ended, and not the low limit for the fan speed; see Section 8.5.85 on page 190.) Whenever a fan failure is detected, the FANn_STALL status bit in the Status Register 2 (see Section 8.5.24 on page 165) and the FANn_STS bit in the HM Sensor Status Register 2 (see Section 8.4.9 on page 148) are both set to 1. A state is associated with the fan condition: a “Good” state is when neither condition for fan failure occurs; a “Fail” state is when at least one condition for fan failure occurs. Whenever the fan state changes, the FANn_EV bit in the HM Interrupt Status Reg- ister 2 is set (see Section 8.4.5 on page 144). FANn_EV can be enabled to create an IRQ by the associated FANn_EN bit in the HM Interrupt Enable Register 2 (see Section 8.4.7 on page 146). FANn_EV can also be enabled to create an SMI or SCI interrupt by the associated xxx_EN bit in the HM SMI/SCI Enable Register 2 (see Section 8.4.13 on page 150). All status bits and event flags are cleared and fan speed monitoring is disabled while the VDD3 power supply is off. 8.2.8 Fan Speed Control The HM controls fan speeds by creating three FANPWMn outputs. Each output is a Pulse Width Modulation signal that can be used to drive at least one fan. Fan speed control is active only while the VDD3 power supply is on. Start-Up After VDD Power-Up reset, the FANPWM outputs are kept at 0% duty cycle until one of the following occurs: • Two seconds elapse from the time that VDD3 exists. In this case, the fans are set to the value contained in the asso- ciated FANPWMn MAX Duty registers (see Section 8.5.82 on page 189 to Section 8.5.84). • START bit of the Configuration registers is set (see Section 8.5.22 on page 163). In this case, the FANPWM outputs are controlled according to the FANPWMn Control Configuration registers (see Section 8.5.76 on page 187 to Section 8.5.78). Control Modes Fan speed can be controlled using one of four modes, chosen by the MODE field in the FANPWMn Control Configuration registers (see Section 8.5.76 on page 187 to Section 8.5.78): • Disabled - The fan is stopped. • Constantly On - The Fan duty cycle is set to the value contained in the associated FANPWMn MAX Duty register. • Manual - The Fan speed is set by writing the required duty cycle to the FANPWM ‘n’ Current Duty register; see Section 8.5.17 on page 161 to Section 8.5.19. In the other three modes, these registers are RO and reflect the duty cycle created by the HM. During spin-up, these registers return either 0 or the target duty cycle (according to the SPIN_DUTY bit in the Extended FANPWM Control 1 register). • Automatic - The FANPWM output is controlled by temperature data of one or more temperature zones (the MODE field also selects the temperature zones for each FANPWM output). In Automatic mode: — The HM implements a linear transfer function between the temperature data of the associated zones and the duty cycle of the FANPWM output. The translation between temperature and duty cycle is done in two stages. In the first stage the temperature is translated to unsigned normalized temperature (see Figure 31 on page 135). In the second stage the normalized temperature is translated to a duty cycle value (see Figure 32 on page 135). The use of the normalized temperature is essential if more than one temperature zone supplies temperature information for control- ling the fans. Table 52. Minimum Equivalent Fan Speed for Fan Failure Conditions Measurement Mode TPPR Low Speed Condition Fan Stalled Condition Speed FAN_MIN_MSB/LSB Setting Speed Condition (TACH_HIGH/LOW = FFFFh, or less than ‘n’ edges) Mode 1 1 PPR 100 RPM D2F0h 100 RPM 3 edges 2 PPR 5 edges Mode 2 1 PPR 1300 RPM 1039h 1300 RPM 2 edges 2 PPR 650 RPM 2073h 650 RPM Winbond Electronics Corp. Advanced PC Product Center |
|
Link URL |
| Does ALLDATASHEET help your business so far? [ DONATE ] |
About Alldatasheet | Advertisement | Contact us | Privacy Policy | Link to Datasheet | Link Exchange | Manufacturer List All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |