| Electronic Components Datasheet Search |
|
CS48L32 Datasheet(PDF) 26 Page - Cirrus Logic |
|
|
|||||||||||||||||||||||||||||
CS48L32 Datasheet(HTML) 26 Page - Cirrus Logic |
|
26 / 192 page ![]() 26 Cirrus Logic DS1219F4 CS48L32 4.2 Input Signal Path 4.2.2 Analog Line Input Line inputs can be connected to the CS48L32 in a similar manner to the mic inputs. Single-ended and differential configurations are supported on each analog input path, using the IN1x_SRC bits as described in Section 4.2.6. The analog line input configurations are shown in Fig. 4-8 and Fig. 4-9. Note that the microphone bias (MICBIAS) is not used for line input connections. 4.2.3 PDM (DMIC) Input The CS48L32 supports as many as four PDM input channels, ideal for use with digital microphone (DMIC) input and other digital interfaces. The IN1 input path supports analog and digital input; digital (PDM) operation is selected using IN1_ MODE as described in Section 4.2.6. In PDM mode, two channels of audio data are multiplexed on the associated INn_PDMDATA pin. Each stereo interface is clocked using the respective INn_PDMCLK pin. If PDM input is enabled, the CS48L32 outputs the CLK signal on the applicable INn_PDMCLK pins. The CLK frequency is controlled by the respective INn_OSR field, as described in Table 4-1 and Table 4-3. Note that the input-path PDM interfaces operate in Master Mode only—the clock (CLK) signal is generated by the CS48L32. Note that, if ultrasonic signal detection or demodulation is enabled (see Section 4.2.9), the CLK frequency for the respective input path must be 1.536 MHz or 3.072 MHz. Note that, if the 384 kHz or 768 kHz CLK frequency is selected, the maximum valid sample rate for the respective paths is restricted as described in Table 4-1. If the input sample rates are set globally using IN_RATE (i.e., IN_RATE_ MODE = 0), all input paths are affected similarly. The system clock, SYSCLK, must be present and enabled if using the PDM inputs; see Section 4.8 for details of SYSCLK and the associated registers. The PDM clock frequencies in Table 4-1 assume that the SYSCLK frequency is a multiple of 6.144 MHz (SYSCLK_ FRAC = 0). If the SYSCLK frequency is a multiple of 5.6448 MHz (SYSCLK_FRAC = 1), the PDM clock frequencies are scaled accordingly. Figure 4-8. Single-Ended Line Input Figure 4-9. Differential Line Input Table 4-1. PDM Clock Frequency Condition PDM Clock Frequency Valid Sample Rates Signal Passband INn_OSR = 000 384 kHz Up to 48 kHz Up to 4 kHz INn_OSR = 001 768 kHz Up to 96 kHz Up to 8 kHz INn_OSR = 010 1.536 MHz Up to 192 kHz Up to 20 kHz INn_OSR = 011 2.048 MHz Up to 192 kHz Up to 20 kHz INn_OSR = 100 2.4576 MHz Up to 192 kHz Up to 20 kHz INn_OSR = 101 3.072 MHz Up to 192 kHz Up to 20 kHz INn_OSR = 110 6.144 MHz Up to 192 kHz Up to 96 kHz GND Line To ADC VREF PGA + – IN1LN, IN1RN IN1LP, IN1RP To ADC VREF Line PGA + – IN1LN, IN1RN IN1LP, IN1RP |
|
Link URL |
| Does ALLDATASHEET help your business so far? [ DONATE ] |
About Alldatasheet | Advertisement | Contact us | Privacy Policy | Link to Datasheet | Link Exchange | Manufacturer List All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |