Back Button R2000 Datasheet HTML 46Page - List of Unclassifed Manufacturers R2000 Datasheet HTML 47Page - List of Unclassifed Manufacturers R2000 Datasheet HTML 48Page - List of Unclassifed Manufacturers R2000 Datasheet HTML 49Page - List of Unclassifed Manufacturers R2000 Datasheet HTML 50Page - List of Unclassifed Manufacturers R2000 Datasheet HTML 51Page - List of Unclassifed Manufacturers R2000 Datasheet HTML 52Page - List of Unclassifed Manufacturers R2000 Datasheet HTML 53Page - List of Unclassifed Manufacturers R2000 Datasheet HTML 54Page - List of Unclassifed Manufacturers Next Button
Zoom Inzoom in Zoom Outzoom out
 50 / 75 page
background image
Indy® R2000 Electrical, Mechanical, & Thermal Specification
Revision 2.0, Copyright © 2015, Impinj, Inc.
50
Addr.
Name
R/W
Bit
Description
Reset
Type
Comment
282
RSSI_BLOCK_
AVG
R/W
15:13
12:10
9:7
6
5:3
2:0
Averaging shift during
timeout.
Averaging of RT NB RSSI
Averaging of RT WB RSSI
Enable real-time RSSI
Averaging of NB RSSI
Averaging of WB RSSI
h0000
The real-time RSSI
averaging can take the
following values (both
narrow- and wide-band):
0 = 1 sample.
1 = 2 samples.
2 = 4 samples.
3 = 8 samples.
4 = 16 samples.
5 = 32 samples.
6 = 64 samples.
7 = 128 samples.
The normal narrow-band
RSSI averaging can
assume the following
values:
0 = 8 samples.
1 = 16 samples.
2 = 32 samples.
3 = 64 samples.
4 = 128 samples.
5 = 256 samples.
6 = 512 samples.
7 = 1024 samples.
The normal wide-band
RSSI averaging can
assume the following
values:
0 = 32 samples.
1 = 64 samples.
2 = 128 samples.
3 = 256 samples.
4 = 512 samples.
5 = 1024 samples.
6 = 2048 samples
7 = 4096 samples.
283
RSSI_RUNNING_
AVG
R/W
5:3
2:0
Running averaging of RT NB
RSSI
Running averaging of RT WB
RSSI
h0000
The size of the running
average of the real-time
RSSI can take the
following values (both
narrow- and wide-band):
0 = 1 sample.
1 = 2 samples.
2 = 4 samples.
3 = 8 samples.
4 = 16 samples.
284
RSSI_LOG_SMALL
R
15:8
7:0
Narrow-band RSSI value in
log2
Wide-band RSSI value in
log2
h0000
Block average only.
This is only updated on
measurement commands
and other triggers.
Narrow band: 5 bits
exponent, 3 bits mantissa.
Wide band: 4 bits
exponent, 4 bits mantissa.
285
RSSI_RT_AVG_
LOG_SML
R
15:8
7:0
Real-time WB RSSI value in
log2
Real-time NB RSSI value in
log2
h0000
Running average over
block average.
This is the truncated
version of registers h288
and h289.
Narrow band: 5 bits
exponent, 3 bits mantissa.
Wide band: 4 bits
exponent, 4 bits mantissa.



Html Pages

1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55 56 57 58 59 60 61 62 63 64 65 66 67 68 69 70 71 72 73 74 75


Datasheet Download

Go To PDF Page


Link URL



Does ALLDATASHEET help your business so far?  [ DONATE ] 

About Alldatasheet   |   Advertisement   |   Contact us   |   Privacy Policy   |   Link to Datasheet    |   Link Exchange   |   Manufacturer List
All Rights Reserved©Alldatasheet.com


Mirror Sites
English : Alldatasheet.com  |   English : Alldatasheet.net  |   Chinese : Alldatasheetcn.com  |   German : Alldatasheetde.com  |   Japanese : Alldatasheet.jp
Russian : Alldatasheetru.com  |   Korean : Alldatasheet.co.kr  |   Spanish : Alldatasheet.es  |   French : Alldatasheet.fr  |   Italian : Alldatasheetit.com
Portuguese : Alldatasheetpt.com  |   Polish : Alldatasheet.pl  |   Vietnamese : Alldatasheet.vn
Indian : Alldatasheet.in  |   Mexican : Alldatasheet.com.mx  |   British : Alldatasheet.co.uk  |   New Zealand : Alldatasheet.co.nz
Family Site : ic2ic.com  |   icmetro.com