49 / 77 page ![]() ADT7467 Rev. 3 | Page 49 of 77 | www.onsemi.com STEP 8: THYST FOR TEMPERATURE CHANNELS THYST is the amount of extra cooling a fan provides after the temperature measured drops below TMIN before the fan turns off. The premise for temperature hysteresis (THYST) is that, without it, the fan would merely chatter or cycle on and off repeatedly whenever the temperature hovered near the TMIN setting. The THYST value determines the amount of time needed for the system to cool down or heat up as the fan turns on and off. Values of hysteresis are programmable in the range 1°C to 15°C. Larger values of THYST prevent the fans from chattering on and off. The THYST default value is set at 4°C. The THYST setting not only applies to the temperature hysteresis for fan on/off, but also is used for the TTHERM hysteresis value, as described in Step 6: TRANGE for Temperature Channels. There- fore, programming Register 0x6D and Register 0x6E sets the hysteresis for both fan on/off and the THERM function. Hysteresis Registers Register 0x6D, Remote 1 and local hysteresis register <7:4>, Remote 1 temperature hysteresis (4°C default) <3:0>, local temperature hysteresis (4°C default) Register 0x6E, Remote 2 temperature hysteresis register <7:4>, Remote 2 temperature hysteresis (4°C default) In some applications, it is required that fans continue to run at PWMMIN, instead of turning off when the temperature drops below TMIN. Bits <7:5> of Enhanced Acoustics Register 1 (0x62) allow the fans to be either turned off or kept spinning below TMIN. If the fans are always on, the THYST value has no effect on the fan when the temperature drops below TMIN. REAR CHASSIS FRONT CHASSIS CPU FAN SINK LOCAL = VRM TEMP PWM1 PWM2 TACH1 TACH2 TACH3 PWM3 REMOTE 1 = AMBIENT TEMP REMOTE 2 = CPU TEMP MUX THERMAL CALIBRATION 0% TMIN TRANGE THERMAL CALIBRATION 100% 0% TMIN TRANGE THERMAL CALIBRATION 100% 0% TMIN TRANGE TACHOMETER 1 MEASUREMENT PWM CONFIG PWM MIN RAMP CONTROL (ACOUSTIC ENHANCEMENT) PWM GENERATOR TACHOMETER 2 MEASUREMENT PWM CONFIG PWM MIN RAMP CONTROL (ACOUSTIC ENHANCEMENT) PWM GENERATOR TACHOMETER 3 AND 4 MEASUREMENT PWM CONFIG PWM MIN RAMP CONTROL (ACOUSTIC ENHANCEMENT) PWM GENERATOR 100% TMIN 0% 100% TRANGE TTHERM Figure 68. The THYST Value Applies to Fan On/Off Hysteresis and THERM Hysteresis |
|
Link URL |
| Does ALLDATASHEET help your business so far? [ DONATE ] |
About Alldatasheet | Advertisement | Contact us | Privacy Policy | Link to Datasheet | Link Exchange | Manufacturer List All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |