74 / 77 page ![]() ADT7467 Rev. 3 | Page 74 of 77 | www.onsemi.com Table 56. Register 0x79—THERM Timer Status Register (Power-On Default = 0x00) Bit Name R/W Description <7:1> TMR Read only Times how long THERM input is asserted. These seven bits read 0 until the THERM assertion time exceeds 45.52 ms. <0> ASRT/TMR0 Read only This bit is set high upon the assertion of the THERM input and is cleared upon a read. If the THERM assertion time exceeds 45.52 ms, this bit is set and becomes the LSB of the 8-bit TMR reading. This allows THERM assertion times from 45.52 ms to 5.82 sec to be reported back with a resolution of 22.76 ms. Table 57. Register 0x7A—THERM Timer Limit Register (Power-On Default = 0x00) Bit Name R/W Description <7:0> LIMT Read/write Sets the maximum THERM assertion length before an interrupt is generated. This is an 8-bit limit with a resolution of 22.76 ms, allowing THERM assertion limits of 45.52 ms to 5.82 sec to be programmed. If the THERM assertion time exceeds this limit, Bit 5 (F4P) of Interrupt Status Register 2 (0x42) is set. If the limit value is 0x00, an interrupt is generated immediately upon the assertion of the THERM input. Table 58. Register 0x7B—TACH Pulses per Revolution Register (Power-On Default = 0x55) Bit Name R/W Description <1:0> FAN1 Read/write Sets the number of pulses to be counted when measuring Fan 1 speed. Can be used to determine fan pulses per revolution for an unknown fan type. Pulses Counted 00 = 1 01 = 2 (default) 10 = 3 11 = 4 <3:2> FAN2 Read/write Sets the number of pulses to be counted when measuring Fan 2 speed. Can be used to determine fan pulses per revolution for an unknown fan type. Pulses Counted 00 = 1 01 = 2 (default) 10 = 3 11 = 4 <5:4> FAN3 Read/write Sets the number of pulses to be counted when measuring Fan 3 speed. Can be used to determine fan pulses per revolution for an unknown fan type. Pulses Counted 00 = 1 01 = 2 (default) 10 = 3 11 = 4 <7:6> FAN4 Read/write Sets the number of pulses to be counted when measuring Fan 4 speed. Can be used to determine fan pulses per revolution for an unknown fan type. Pulses Counted 00 = 1 01 = 2 (default) 10 = 3 11 = 4 Table 59. Register 0x7C—Configuration Register 5 (Power-On Default = 0x00) Bit Name R/W1 Description <0> Twos Compl Read/write Twos Compl = 1 sets the temperature range to twos complement temperature range. Twos Compl = 0 changes the temperature range to Offset 64. When this bit is changed, the ADT7467 interprets all relevant temperature register values as defined by this bit. <1> LF/HF Read/write Sets the PWM drive frequency to high frequency mode (0) or low frequency mode (1). <2> GPIOD Read/write GPIO direction. When GPIO function is enabled, this determines whether the GPIO is an input (0) or an output (1). <3> GPIOP Read/write GPIO polarity. When the GPIO function is enabled and programmed as an output, this bit determines whether the GPIO is active low (0) or high (1). <4:7> RES Read/write Unused. 1 This register becomes a read-only register when the Configuration Register 1 LOCK bit is set to 1. Any subsequent attempts to write to this register fail. |
|
Link URL |
| Does ALLDATASHEET help your business so far? [ DONATE ] |
About Alldatasheet | Advertisement | Contact us | Privacy Policy | Link to Datasheet | Link Exchange | Manufacturer List All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |