| Electronic Components Datasheet Search |
|
ADT7467ARQZ-R7 Datasheet(PDF) 20 Page - ON Semiconductor |
|
|
|||||||||||||||||||||||||||||
ADT7467ARQZ-R7 Datasheet(HTML) 20 Page - ON Semiconductor |
|
20 / 77 page ![]() ADT7467 Rev. 3 | Page 20 of 77 | www.onsemi.com Table 9. Conversion Time with Averaging Disabled Channel Measurement Time Voltage Channels 0.7 ms Remote Temperature 1 7 ms Remote Temperature 2 7 ms Local Temperature 1.3 ms Table 10. Conversion Time with Averaging Enabled Channel Measurement Time Voltage Channels 11 ms Remote Temperature 39 ms Local Temperature 12 ms Single-Channel ADC Conversions Setting Bit 6 of Configuration Register 2 (0x73) places the ADT7467 into single-channel ADC conversion mode. In this mode, users can read a single temperature channel only. The appropriate ADC channel is selected by writing to Bits <7:5> of the TACH1 minimum high byte register (0x55). Table 11. Channel Selection Bits <7:5>, Register 0x55 Channel Selected 101 Remote 1 temperature 110 Local temperature 111 Remote 2 temperature Configuration Register 2 (0x73) <4> = 1, averaging off <6> = 1, single-channel convert mode TACH1 Minimum High Byte (0x55) <7:5> selects ADC channel for single-channel convert mode Overtemperature Events Overtemperature events on a temperature channel can be automatically detected and dealt with in automatic fan speed control mode. Register 0x6A to Register 0x6C contain the THERM temperature limits. When a temperature exceeds its THERM temperature limit, all PWM outputs run at the maxi- mum PWM duty cycle (0x38, 0x39, 0x3A); therefore, fans run at the fastest speed allowed and continue running at this speed until the temperature drops below THERM minus hysteresis. (This can be disabled by setting the BOOST bit in Configuration Register 3, Bit 2, Register 0x78.) The hysteresis value for that THERM temperature limit is the value programmed into Register 0x6D and Register 0x6E (hysteresis registers). The default hysteresis value is 4°C. FANS TEMPERATURE 100% HYSTERESIS (°C) THERM LIMIT Figure 27. THERM Temperature Limit Operation |
|
Link URL |
| Does ALLDATASHEET help your business so far? [ DONATE ] |
About Alldatasheet | Advertisement | Contact us | Privacy Policy | Link to Datasheet | Link Exchange | Manufacturer List All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |