| Electronic Components Datasheet Search |
|
ADT7467ARQZ-R7 Datasheet(PDF) 72 Page - ON Semiconductor |
|
|
|||||||||||||||||||||||||||||
ADT7467ARQZ-R7 Datasheet(HTML) 72 Page - ON Semiconductor |
|
72 / 77 page ![]() ADT7467 Rev. 3 | Page 72 of 77 | www.onsemi.com Table 47. Register 0x70—Remote 1 Temperature Offset (Power-On Default = 0x00) Bit R/W1 Description <7:0> Read/write Allows a twos complement offset value to be automatically added to or subtracted from the Remote 1 temperature reading. This is to compensate for any inherent system offsets such as PCB trace resistance. LSB value = 0.5°C. 1 This register becomes a read-only register when the Configuration Register 1 LOCK bit is set to 1. Any subsequent attempts to write to this register fail. Table 48. Register 0x71—Local Temperature Offset (Power-On Default = 0x00) Bit R/W1 Description <7:0> Read/write Allows a twos complement offset value to be automatically added to or subtracted from the local temperature reading. LSB value = 0.5°C. 1 This register becomes a read-only register when the Configuration Register 1 LOCK bit is set to 1. Any subsequent attempts to write to this register fail. Table 49. Register 0x72—Remote 2 Temperature Offset (Power-On Default = 0x00) Bit R/W1 Description <7:0> Read/write Allows a twos complement offset value to be automatically added to or subtracted from the Remote 2 temperature reading. This is to compensate for any inherent system offsets such as PCB trace resistance. LSB value = 0.5°C. 1 This register becomes a read-only register when the Configuration Register 1 LOCK bit is set to 1. Any subsequent attempts to write to this register fail. Table 50. Register 0x73—Configuration Register 2 (Power-On Default = 0x00) Bit Name R/W1 Description <0> AIN1 Read/write AIN1 = 0, speed of 3-wire fans measured using the TACH output from the fan. AIN1 = 1, Pin 6 is reconfigured to measure the speed of 2-wire fans using an external sensing resistor and coupling capacitor. AIN voltage threshold is set via Configuration Register 4 (0x7D). Only relevant in low frequency mode. <1> AIN2 Read/write AIN2 = 0, speed of 3-wire fans measured using the TACH output from the fan. AIN2 = 1, Pin 7 is reconfigured to measure the speed of 2-wire fans using an external sensing resistor and coupling capacitor. AIN voltage threshold is set via Configuration Register 4 (0x7D). Only relevant in low frequency mode. <2> AIN3 Read/write AIN3 = 0, speed of 3-wire fans measured using the TACH output from the fan. AIN3 = 1, Pin 4 is reconfigured to measure the speed of 2-wire fans using an external sensing resistor and coupling capacitor. AIN voltage threshold is set via Configuration Register 4 (0x7D). Only relevant in low frequency mode. <3> AIN4 Read/write AIN4 = 0, speed of 3-wire fans measured using the TACH output from the fan. AIN4 = 1, Pin 9 is reconfigured to measure the speed of 2-wire fans using an external sensing resistor and coupling capacitor. AIN voltage threshold is set via Configuration Register 4 (0x7D). Only relevant in low frequency mode. <4> AVG Read/write AVG = 1, averaging on the temperature and voltage measurements is turned off. This allows measurements on each channel to be made much faster. <5> ATTN Read/write ATTN = 1, the ADT7467 removes the attenuators from the VCCP input. The VCCP input can be used for other functions such as connecting external sensors. <6> CONV Read/write CONV = 1, the ADT7467 is put into a single-channel ADC conversion mode. In this mode, the ADT7467 can be set to read continuously from one input only, for example, Remote 1 temperature. The appropriate ADC channel is selected by writing to bits <7:5> of the TACH1 minimum high byte register (0x55). Bits <7:5>, Register 0x55 000 Reserved 001 VCCP 010 VCC (3.3 V) 011 Reserved 100 Reserved 101 Remote 1 temperature 110 Local temperature 111 Remote 2 temperature <7> SHDN Read/write SHDN = 1, ADT7467 goes into shutdown mode. All PWM outputs assert low (or high depending on the state of the INV bit) to switch off all fans. The PWM current duty cycle registers read 0x00 to indicate that the fans are not being driven. 1 This register becomes a read-only register when the Configuration Register 1 LOCK bit is set to 1. Any subsequent attempts to write to this register fail. |
|
Link URL |
| Does ALLDATASHEET help your business so far? [ DONATE ] |
About Alldatasheet | Advertisement | Contact us | Privacy Policy | Link to Datasheet | Link Exchange | Manufacturer List All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |