21 / 77 page ![]() ADT7467 Rev. 3 | Page 21 of 77 | www.onsemi.com LIMITS, STATUS REGISTERS, AND INTERRUPTS LIMIT VALUES High and low limits are associated with each measurement channel on the ADT7467. These limits form the basis of system-status monitoring in that a status bit can be set for any out-of-limit condition and detected by polling the device. Alternatively, SMBALERT interrupts can be generated to flag a processor or microcontroller of out-of-limit conditions. 8-Bit Limits The following is a list of 8-bit limits on the ADT7467. Voltage Limit Registers Register 0x46 VCCP low limit = 0x00 default Register 0x47 VCCP high limit = 0xFF default Register 0x48 VCC low limit = 0x00 default Register 0x49 VCC high limit = 0xFF default Temperature Limit Registers Register 0x4E Remote 1 temperature low limit = 0x01 default Register 0x4F Remote 1 temperature high limit = 0x7F default Register 0x6A Remote 1 THERM temperature limit = 0xA4 default Register 0x50 local temperature low limit = 0x01 default Register 0x51 local temperature high limit = 0x7F default Register 0x6B local THERM temperature limit = 0xA4 default Register 0x52 Remote 2 temperature low limit = 0x01 default Register 0x53 Remote 2 temperature high limit = 0x7F default Register 0x6C Remote 2 THERM temperature limit = 0xA4 default THERM Limit Register Register 0x7A THERM timer limit = 0x00 default 16-Bit Limits The fan TACH measurements are 16-bit results. The fan TACH limits are also 16 bits, consisting of a high byte and low byte. Because slow or stalled fans are normally the only conditions of interest, only high limits exist for fan TACHs. Because the fan TACH period is measured, exceeding the limit indicates a slow or stalled fan. Fan Limit Registers Register 0x54 TACH1 minimum low byte = 0xFF default Register 0x55 TACH1 minimum high byte = 0xFF default Register 0x56 TACH2 minimum low byte = 0xFF default Register 0x57 TACH2 minimum high byte = 0xFF default Register 0x58 TACH3 minimum low byte = 0xFF default Register 0x59 TACH3 minimum high byte = 0xFF default Register 0x5A TACH4 minimum low byte = 0xFF default Register 0x5B TACH4 minimum high byte = 0xFF default Out-of-Limit Comparisons Once all limits are programmed, the ADT7467 can be enabled for monitoring. The ADT7467 measures all voltage and temperature measurements in round-robin format and sets the appropriate status bit for out-of-limit conditions. TACH measurements are not part of this round-robin cycle. Compari- sons are done differently, depending on whether the measured value is being compared to a high or low limit. High limit: > comparison performed Low limit: ≤ comparison performed Voltage and temperature channels use a window comparator for error detecting and, therefore, have high and low limits. Fan speed measurements use only a low limit. This fan limit is needed only in manual fan control mode. Analog Monitoring Cycle Time The analog monitoring cycle begins when a 1 is written to the start bit (Bit 0) of Configuration Register 1 (0x40). By default, the ADT7463 powers up with this bit set. The ADC measures each analog input in turn and, as each measurement is com- pleted, the result is automatically stored in the appropriate value register. This round-robin monitoring cycle continues unless disabled by writing a 0 to Bit 0 of Configuration Register 1. As the ADC is normally left to free-run in this manner, the time to monitor all analog inputs is normally not of interest because the most recently measured value of an input can be read at any time. For applications where the monitoring cycle time is important, it can be calculated easily. The total number of channels measured is • One dedicated supply voltage input (VCCP) • One supply voltage (VCC pin) • One local temperature • Two remote temperatures As mentioned previously, the ADC performs round-robin conversions. The total monitoring cycle time for averaged voltage and temperature monitoring is 145 ms. The total monitoring cycle time for voltage and temperature monitoring with averaging disabled is 19 ms. The ADT7467 is a derivative of the ADT7468. As a result, the total conversion time for the ADT7467 and ADT7468 are the same, even though the ADT7467 has less monitored channels. |
|
Link URL |
| Does ALLDATASHEET help your business so far? [ DONATE ] |
About Alldatasheet | Advertisement | Contact us | Privacy Policy | Link to Datasheet | Link Exchange | Manufacturer List All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |