34 / 77 page ![]() ADT7467 Rev. 3 | Page 34 of 77 | www.onsemi.com MISCELLANEOUS FUNCTIONS OPERATING FROM 3.3 V STANDBY The ADT7467 has been specifically designed to operate from a 3.3 V STANDBY supply. In computers that support S3 and S5 states, the core voltage of the processor is lowered in these states. If using the dynamic TMIN mode, lowering the core voltage of the processor changes the CPU temperature and changes the dynamics of the system under dynamic TMIN control. Likewise, when monitoring THERM, the THERM timer should be disabled during these states. Dynamic TMIN Control Register 1 (0x36) <1> VCCPLO = 1 When the power is supplied from 3.3 V STANDBY and the VCCP voltage drops below the VCCP low limit, the following occurs: 1. Status Bit 1 (VCCP) in Interrupt Status Register 1 is set. 2. SMBALERT is generated if enabled. 3. THERM monitoring is disabled. The THERM timer should hold its value prior to the S3 or S5 state. 4. Dynamic TMIN control is disabled. This prevents TMIN from being adjusted due to an S3 or S5 state. 5. The ADT7467 is prevented from shutting down. Once the core voltage, VCCP, goes above the VCCP low limit, everything is re-enabled and the system resumes normal operation. XNOR TREE TEST MODE The ADT7467 includes an XNOR tree test mode. This mode is useful for in-circuit test equipment at board-level testing. By applying stimulus to the pins included in the XNOR tree, it is possible to detect opens or shorts on the system board. Figure 47 shows the signals that are exercised in the XNOR tree test mode. The XNOR tree test is invoked by setting Bit 0 (XEN) of the XNOR tree test enable register (0x6F). PWM1/XTO PWM3 PWM2 TACH4 TACH3 TACH2 TACH1 Figure 47. XNOR Tree Test POWER-ON DEFAULT When the ADT7467 is powered up, it polls the VCCP input. If VCCP stays below 0.75 V (the system CPU power rail is not powered up), the ADT7467 assumes the functionality of the default registers after the ADT7467 is addressed via any valid SMBus transaction. If VCC goes high (the system processor power rail is powered up), a fail-safe timer begins to count down. If the ADT7467 is not addressed by a valid SMBus transaction before the fail-safe timeout (4.6 sec) lapses, the ADT7467 drives the fans to full speed. If the ADT7467 is addressed by a valid SMBus transaction after this point, the fans stop and the ADT7467 assumes its default settings and begins normal operation. If VCCP goes high (the system processor power rail is powered up), a fail-safe timer begins to count down. If the ADT7467 is addressed by a valid SMBus transaction before the fail-safe timeout (4.6 sec) lapses, the ADT7467 operates normally, assuming the functionality of all default registers. See the flow chart in Figure 48. ADT7467 IS POWERED UP HAS THE ADT7467 BEEN ACCESSED BY A VALID SMBUS TRANSACTION? IS VCCP ABOVE 0.75V? CHECK VCCP START FAIL-SAFE TIMER HAS THE ADT7467 BEEN ACCESSED BY A VALID SMBUS TRANSACTION? FAIL-SAFE TIMER ELAPSES AFTER THE FAIL-SAFE TIMEOUT HAS THE ADT7467 BEEN ACCESSED BY A VALID SMBUS TRANSACTION? START UP THE ADT7467 NORMALLY RUN THE FANS TO FULL SPEED HAS THE ADT7467 BEEN ACCESSED BY A VALID SMBUS TRANSACTION? SWITCH OFF FANS N N N N N Y Y Y Y Y Figure 48. Power-On Flowchart |
|
Link URL |
| Does ALLDATASHEET help your business so far? [ DONATE ] |
About Alldatasheet | Advertisement | Contact us | Privacy Policy | Link to Datasheet | Link Exchange | Manufacturer List All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |