| Electronic Components Datasheet Search |
|
ADT7467ARQZ-R7 Datasheet(PDF) 36 Page - ON Semiconductor |
|
|
|||||||||||||||||||||||||||||
ADT7467ARQZ-R7 Datasheet(HTML) 36 Page - ON Semiconductor |
|
36 / 77 page ![]() ADT7467 Rev. 3 | Page 36 of 77 | www.onsemi.com DYNAMIC TMIN CONTROL MODE In addition to the automatic fan speed control mode, the ADT7467 has a mode that extends the basic automatic fan speed control loop. Dynamic TMIN control allows the ADT7467 to intelligently adapt the system’s cooling solution to optimize system performance or system acoustics, depending on user or design requirements. Use of dynamic TMIN control alleviates the need to design for worst-case conditions, and it significantly reduces the time required for system design and validation. Designing for Worst-Case Conditions System design must always allow for worst-case conditions. In PC design, the worst-case conditions include, but are not limited to, the following: • Worst-Case Altitude A computer can be operated at different altitudes. The altitude affects the relative air density, which alters the effectiveness of the fan cooling solution. For example, comparing 40°C air temperature at 10,000 ft. to 20°C air temperature at sea level, relative air density is increased by 40%. This means that at a given temperature, the fan can spin 40% slower and make less noise at sea level than it can at 10,000 ft. • Worst-Case Fan Due to manufacturing tolerances, fan speeds in RPM are normally quoted with a tolerance of ±20%. The designer should assume that the fan RPM is 20% below tolerance. This translates to reduced system airflow and elevated system temperature. Note that a difference of 20% in the fans’ tolerance can negatively impact system acoustics because the fans run faster and generate more noise. • Worst-Case Chassis Airflow The same motherboard can be used in a number of different chassis configurations. The design of the chassis and the physical location of fans and components determine the system thermal characteristics. Moreover, for a given chassis, the addition of add-in cards, cables, and other system configuration options can alter the system airflow and reduce the effectiveness of the system cooling solution. The cooling solution can also be inadvertently altered by the end user. (For example, placing a computer against a wall can block the air ducts and reduce system airflow.) FAN I/O CARDS POOR CPU AIRFLOW VENTS POWER SUPPLY CPU DRIVE BAYS GOOD VENTING = GOOD AIR EXCHANGE POOR VENTING = POOR AIR EXCHANGE VENTS FAN I/O CARDS GOOD CPU AIRFLOW FAN VENTS POWER SUPPLY CPU DRIVE BAYS Figure 50. Chassis Airflow Issues • Worst-Case Processor Power Consumption Designing for worst-case CPU power consumption can result in a processor becoming overcooled, generating excess system noise. • Worst-Case Peripheral Power Consumption The tendency is to design to data sheet maximums for peripheral components (again overcooling the system). • Worst-Case Assembly Every system is unique because of manufacturing variations. Heat sinks may be loose fitting or slightly misaligned. Too much or too little thermal grease might be used, or variations in application pressure for thermal interface material could affect the efficiency of the thermal solution. Accounting for manufacturing variations in every system is difficult; therefore, the system must be designed for worst-case conditions. SUBSTRATE HEAT SINK THERMAL INTERFACE MATERIAL INTEGRATED HEAT SPREADER EPOXY THERMAL INTERFACE MATERIAL PROCESSOR TA TJ θCA θSA θTIMS θCTIM θTIMC θJTIM θCS TC TTIM TS TTIM θJA Figure 51. Thermal Model Although a design usually accounts for such worst-case conditions, the system is almost never operated at worst-case conditions. An alternative to designing for the worst case is to use the dynamic TMIN control function. |
|
Link URL |
| Does ALLDATASHEET help your business so far? [ DONATE ] |
About Alldatasheet | Advertisement | Contact us | Privacy Policy | Link to Datasheet | Link Exchange | Manufacturer List All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |