22 / 77 page ![]() ADT7467 Rev. 3 | Page 22 of 77 | www.onsemi.com Fan TACH measurements are made in parallel and are not synchronized with the analog measurements in any way. STATUS REGISTERS The results of limit comparisons are stored in Interrupt Status Register 1 and Interrupt Status Register 2. The status register bit for each channel reflects the status of the last measurement and limit comparison on that channel. If a measurement is within limits, the corresponding status register bit is cleared to 0. If the measurement is out of limit, the corresponding status register bit is set to 1. The state of the various measurement channels can be polled by reading the status registers over the serial bus. In Bit 7 (OOL) of Interrupt Status Register 1 (0x41), 1 means that an out-of-limit event has been flagged in Interrupt Status Register 2. This means that the user also should read Interrupt Status Register 2. Alternatively, Pin 5 or Pin 9 can be configured as an SMBALERT output. This hardware interrupt automatically notifies the system supervisor of an out-of-limit condition. Reading the status registers clears the appropriate status bit if the error condition that caused the interrupt is absent. Status register bits are sticky. Whenever a status bit is set, indicating an out-of-limit condition, it remains set until read, even if the event that caused it is absent. The only way to clear the status bit is to read the status register after the event is absent. Interrupt mask registers (0x74 and 0x75) allow masking of individual interrupt sources to prevent an SMBALERT. However, if a masked interrupt source goes out of limit, its associated status bit is set in the interrupt status registers. Status Register 1 (0x41) Bit 7 (OOL) = 1 denotes that a bit in Status Register 2 is set and that Status Register 2 should be read. Bit 6 (R2T) = 1 indicates that Remote 2 temperature high or low limit has been exceeded. Bit 5 (LT) = 1 indicates that local temperature high or low limit has been exceeded. Bit 4 (R1T) = 1 indicates that Remote 1 temperature high or low limit has been exceeded. Bit 2 (VCC) = 1 indicates that VCC high or low limit has been exceeded. Bit 1 (VCCP) = 1 indicates that VCCP high or low limit has been exceeded. Status Register 2 (0x42) Bit 7 (D2) = 1 indicates an open or short on D2+/D2– inputs. Bit 6 (D1) = 1 indicates an open or short on D1+/D1– inputs. Bit 5 (F4P) = 1 indicates Fan 4 has dropped below minimum speed. Alternatively, if the THERM function is used, it indicates that the THERM limit has been exceeded. Bit 4 (FAN3) = 1 indicates Fan 3 has dropped below minimum speed. Bit 3 (FAN2) = 1 indicates Fan 2 has dropped below minimum speed. Bit 2 (FAN1) = 1 indicates Fan 1 has dropped below minimum speed. Bit 1 (OVT) = 1 indicates a THERM overtemperature limit has been exceeded. INTERRUPTS SMBALERT Interrupt Behavior The ADT7467 can be polled for status, or an SMBALERT interrupt can be generated for out-of-limit conditions. It is important to note how the SMBALERT output and status bits behave when writing interrupt handler software. “STICKY” STATUS BIT HIGH LIMIT TEMPERATURE CLEARED ON READ (TEMP BELOW LIMIT) TEMP BACK IN LIMIT (STATUS BIT STAYS SET) SMBALERT Figure 28. SMBALERT and Status Bit Behavior Figure 28 shows how the SMBALERT output and sticky status bits behave. Once a limit is exceeded, the corresponding status bit is set to 1. The status bit remains set until the error condition subsides and the status register is read. The status bits are re- ferred to as sticky because they remain set until read by software. This ensures that an out-of-limit event cannot be missed if software is polling the device periodically. Note that the SMBALERT output remains low both for the duration that a reading is out of limit and until the status register has been read. This has implications on how software handles the interrupt. Handling SMBALERT Interrupts To prevent the system from being tied up with servicing inter- rupts, it is recommend to handle the SMBALERT interrupt as follows: 1. Detect the SMBALERT assertion. 2. Enter the interrupt handler. 3. Read the status registers to identify the interrupt source. |
|
Link URL |
| Does ALLDATASHEET help your business so far? [ DONATE ] |
About Alldatasheet | Advertisement | Contact us | Privacy Policy | Link to Datasheet | Link Exchange | Manufacturer List All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |