51 / 75 page ![]() ADT7490 http://onsemi.com 51 Table 32. Register 0x36 — PECI Configuration Register 1 (Power−On Default = 0x00) Bit No. Mnemonic R/W (Note 1) Description [2:0] AVG[2:0] R/W PECI Smoothing Interval. These bits set the duration over which smoothing is carried out on the PECI data read. Note that the PECI smoothing interval is equal to the PECI register update interval. The smoothing interval is calculated using the following formula: Smooth Interval = #reads x (tBIT x 67 x #CPU + tIDLE) where: #reads is the number of readings defined below. tBIT is the negotiated bit rate. 67 is the number of bits in each PECI reading. #CPU is the number of CPUs providing PECI data (1 to 4). tIDLE = 14 ms, the delay between consecutive reads. Bit Code Number of PECI Readings 000 001 010 011 100 101 110 111 16 2048 4096 8192 16384 32768 65536 Reserved [3] DOM0 R/W CPU Domain Count information. Set to 0 indicates that CPU 1 associated with the PECI0 reading has a single domain (default). Set to 1 indicates that the system CPU 1 contains two domains. [4] REPLACE R/W If this bit is set to 0, it indicates that the ADT7490 is operating in standard mode. If this bit is set to 1, the Remote 1 Temperature register (Register 0x25) is overwritten by PECI0 information (Register 0x33) and vice versa. Note that in this mode, all associated user programmable limit and fan control registers are also swapped and should be programmed in the appropriate PECI or absolute temperature format. [7:5] RES R Reserved. 1. These registers become read-only when the Configuration Register 1 (0x40) LOCK bit is set to 1. Any subsequent attempts to write to these registers fail. Table 33. Maximum PWM Duty Cycle (Power−On Default = 0xFF) (Note 1) Register Address R/W (Note 2) Description 0x38 R/W Maximum duty cycle for PWM1 output, default = 100% (0xFF). 0x39 R/W Maximum duty cycle for PWM2 output, default = 100% (0xFF). 0x3A R/W Maximum duty cycle for PWM3 output, default = 100% (0xFF). 1. These registers set the maximum PWM duty cycle of the PWM output. 2. These registers become read-only when the Configuration Register 1 (0x40) LOCK bit is set to 1. Any subsequent attempts to write to these registers fail. Table 34. PECI TMIN Register (Power−On Default = 0xE0, Value = −32) Register Address R/W (Note 1) Description 0x3B R/W PECI TMIN. When the PECI measurement exceeds PECI TMIN, the appropriate fans run at PWMMIN and increase according to the automatic fan speed control slope. 1. This register becomes read-only when the Configuration Register 1 (0x40) LOCK bit is set. Any further attempts to write to this register have no effect. |
|
Link URL |
| Does ALLDATASHEET help your business so far? [ DONATE ] |
About Alldatasheet | Advertisement | Contact us | Privacy Policy | Link to Datasheet | Link Exchange | Manufacturer List All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |