| Electronic Components Datasheet Search |
|
ADT7490ARQZ-R7 Datasheet(PDF) 28 Page - ON Semiconductor |
|
|
|||||||||||||||||||||||||||||
ADT7490ARQZ-R7 Datasheet(HTML) 28 Page - ON Semiconductor |
|
28 / 75 page ![]() ADT7490 http://onsemi.com 28 THERM Hysteresis Setting Bit 0 of Configuration Register 7 (0x11) disables THERM hysteresis. If THERM hysteresis is enabled and THERM is disabled (Bit 2 of Configuration Register 4, 0x7D), the THERM event is not reflected in the status register and the fans do not go to full speed. If THERM hysteresis is disabled and THERM is disabled (Bit 2 of Configuration Register 4, 0x7D) and assuming the appropriate pin is configured as THERM, the THERM pin asserts low when a THERM event occurs. If THERM and THERM hysteresis are both enabled, the THERM output asserts as expected. THERM Operation in Manual Mode In manual mode, THERM events do not cause fans to go to full speed, unless Bit 5 of Configuration Register 1 (0x40) is set to 1. Additionally, Bit 3 of Configuration Register 4 (0x7D) can be used to select PWM speed on THERM event (100% or maximum PWM). Bit 2 in Configuration Register 4 (0x7D) can be set to disable THERM events from affecting the fans. Fan Drive Using PWM Control The ADT7490 uses pulse−width modulation (PWM) to control fan speed. This relies on varying the duty cycle (or on/off ratio) of a square wave applied to the fan to vary the fan speed. The external circuitry required to drive a fan using PWM control is extremely simple. For 4−wire fans, the PWM drive may need only a pullup resistor. In many cases, the 4−wire fan PWM input has a built−in, pullup resistor. The ADT7490 PWM frequency can be set to a selection of low frequencies or a single high PWM frequency. The low frequency options are used for 3−wire fans, while the high frequency option is usually used with 4−wire fans. For 3−wire fans, a single N−channel MOSFET is the only drive device required. The specifications of the MOSFET depend on the maximum current required by the fan being driven and the input capacitance of the FET. Because a 10 k W (or greater) resistor must be used as a PWM pullup, an FET with large input capacitance can cause the PWM output to become distorted and adversely affect the fan control range. This is a requirement only when using high frequency PWM mode. Typical notebook fans draw a nominal 170 mA, therefore, SOT devices can be used where board space is a concern. In desktops, fans typically draw 250 mA to 300 mA each. If several fans are driven in parallel from a single PWM output or drive larger server fans, the MOSFET must handle the higher current requirements. The only other stipulation is that the MOSFET should have a gate voltage drive, VGS < 3.3 V, for direct interfacing to the PWM output pin. The MOSFET should also have a low on resistance to ensure that there is not a significant voltage drop across the FET, which would reduce the voltage applied across the fan and, therefore, the maximum operating speed of the fan. Figure 36 shows how to drive a 3−wire fan using PWM control. Figure 36. Driving a 3−Wire Fan Using an N−Channel MOSFET ADT7490 TACH PWM 12V FAN Q1 NDT3055L TACH 3.3V 12V 12V 4.7k 10k 1N4148 W W 10kW 10kW Figure 36 uses a 10 k W pullup resistor for the TACH signal. This assumes that the TACH signal is an open−collector from the fan. In all cases, the TACH signal from the fan must be kept below 3.6 V maximum to prevent damaging the ADT7490. Figure 37 shows a fan drive circuit using an NPN transistor such as a general−purpose MMBT2222. While these devices are inexpensive, they tend to have much lower current handling capabilities and higher on resistance than MOSFETs. When choosing a transistor, care should be taken to ensure that it meets the fan’s current requirements. Ensure that the base resistor is chosen so that the transistor is saturated when the fan is powered on. Figure 37. Driving a 3−Wire Fan Using an NPN Transistor ADT7490 TACH TACH PWM 12V FAN Q1 MMBT2222 3.3V 12V 12V 470 4.7k 1N4148 10kW 10kW W W Because the fan drive circuitry in 4−wire fans is not switched on or off, as with previous PWM driven/powered fans, the internal drive circuit is always on and uses the PWM input as a signal instead of a power supply. This enables the internal fan drive circuit to perform better than 3−wire fans, especially for high frequency applications. Figure 38 shows a typical drive circuit for 4−wire fans. |
|
Link URL |
| Does ALLDATASHEET help your business so far? [ DONATE ] |
About Alldatasheet | Advertisement | Contact us | Privacy Policy | Link to Datasheet | Link Exchange | Manufacturer List All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |