Back Button DS9101 Datasheet HTML 14Page - Maxim Integrated Products DS9101 Datasheet HTML 15Page - Maxim Integrated Products DS9101 Datasheet HTML 16Page - Maxim Integrated Products DS9101 Datasheet HTML 17Page - Maxim Integrated Products DS9101 Datasheet HTML 18Page - Maxim Integrated Products DS9101 Datasheet HTML 19Page - Maxim Integrated Products DS9101 Datasheet HTML 20Page - Maxim Integrated Products DS9101 Datasheet HTML 21Page - Maxim Integrated Products DS9101 Datasheet HTML 22Page - Maxim Integrated Products Next Button
Zoom Inzoom in Zoom Outzoom out
 18 / 55 page
background image
Hygrochron Temperature/Humidity Logger
iButton with 8KB Data-Log Memory
18
______________________________________________________________________________________
Latest Temperature Conversion Result Register Bitmap
ADDRESS
BIT 7
BIT 6
BIT 5
BIT 4
BIT 3
BIT 2
BIT 1
BIT 0
BYTE
020Ch
T2
T1
T0
0
0
0
0
0
TRL
020Dh
T10
T9
T8
T7
T6
T5
T4
T3
TRH
Temperature Conversion
The DS1923’s temperature range begins at -20°C and
ends at +85°C. Temperature values are represented as
an 8-bit or 16-bit unsigned binary number with a resolu-
tion of 0.5°C in 8-bit mode and 0.0625°C in 16-bit
mode.
The higher temperature byte TRH is always valid. In
16-bit mode, only the three highest bits of the lower
byte TRL are valid. The five lower bits all read 0. TRL is
undefined if the device is in 8-bit temperature mode. An
out-of-range temperature reading is indicated as 00h or
0000h when too cold and FFh or FFE0h when too hot.
With TRH and TRL representing the decimal equivalent
of a temperature reading, the temperature value is cal-
culated as:
ϑ(°C) = TRH/2 - 41 + TRL/512 (16-bit mode,
TLFS = 1, see address 0213h)
ϑ(°C) = TRH/2 - 41 (8-bit mode, TLFS = 0,
see address 0213h)
This equation is valid for converting temperature read-
ings stored in the data-log memory as well as for data
read from the Latest Temperature Conversion Result
register.
To specify the temperature alarm thresholds, the previ-
ous equations are resolved to:
TALM = 2 x
ϑ(°C) + 82
Because the temperature alarm threshold is only one
byte, the resolution or temperature increment is limited to
0.5°C. The TALM value must be converted into hexadec-
imal format before it can be written to one of the
Temperature Alarm Threshold registers (Low Alarm
address 0208h; High Alarm address 0209h).
Independent of the conversion mode (8-bit or 16-bit),
only the most significant byte of a temperature conver-
sion is used to determine whether an alarm is generated.
Humidity Conversion
In addition to temperature, the DS1923 can log humidi-
ty data in an 8-bit or 16-bit format. Humidity values are
represented as 8-bit or 16-bit unsigned binary numbers
with a resolution of 0.64%RH in the 8-bit mode and
0.04%RH in the 16-bit mode.
The DS1923 reads data from its humidity sensor when-
ever a Forced Conversion command is executed (see
the
Memory and Control Function Commands section)
or during a mission if the device is set up to log humidi-
ty data. Regardless of its setup, the DS1923 always
reads 16 bits from the humidity sensor. The result of the
latest humidity reading is found at address 020Eh (low
byte) and 020Fh (high byte). The most significant bit
read from the humidity sensor can always be found as
H11 at address 020Fh. Due to the 12-bit digital output
of the humidity sensor, the lower 4 bits in 16-bit format
are undefined.
Table 1. Temperature Conversion Examples
TRH
TRL
MODE
HEX
DECIMAL
HEX
DECIMAL
(°C)
8-Bit
54h
84
—
—
1.0
8-Bit
17h
23
—
—
-29.5
16-Bit
54h
84
00h
0
1.000
16-Bit
17h
23
60h
96
-29.3125
Table 2. Temperature Alarm Threshold Examples
TALM
(°C)
HEX
DECIMAL
25.5
85h
133
-10.0
3Eh
62



Html Pages

1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55


Datasheet Download

Go To PDF Page


Link URL



Does ALLDATASHEET help your business so far?  [ DONATE ] 

About Alldatasheet   |   Advertisement   |   Contact us   |   Privacy Policy   |   Link to Datasheet    |   Link Exchange   |   Manufacturer List
All Rights Reserved©Alldatasheet.com


Mirror Sites
English : Alldatasheet.com  |   English : Alldatasheet.net  |   Chinese : Alldatasheetcn.com  |   German : Alldatasheetde.com  |   Japanese : Alldatasheet.jp
Russian : Alldatasheetru.com  |   Korean : Alldatasheet.co.kr  |   Spanish : Alldatasheet.es  |   French : Alldatasheet.fr  |   Italian : Alldatasheetit.com
Portuguese : Alldatasheetpt.com  |   Polish : Alldatasheet.pl  |   Vietnamese : Alldatasheet.vn
Indian : Alldatasheet.in  |   Mexican : Alldatasheet.com.mx  |   British : Alldatasheet.co.uk  |   New Zealand : Alldatasheet.co.nz
Family Site : ic2ic.com  |   icmetro.com