| Electronic Components Datasheet Search |
|
DS9101 Datasheet(PDF) 18 Page - Maxim Integrated Products |
|
|
|||||||||||||||||||||||||||||
DS9101 Datasheet(HTML) 18 Page - Maxim Integrated Products |
|
18 / 55 page ![]() Hygrochron Temperature/Humidity Logger iButton with 8KB Data-Log Memory 18 ______________________________________________________________________________________ Latest Temperature Conversion Result Register Bitmap ADDRESS BIT 7 BIT 6 BIT 5 BIT 4 BIT 3 BIT 2 BIT 1 BIT 0 BYTE 020Ch T2 T1 T0 0 0 0 0 0 TRL 020Dh T10 T9 T8 T7 T6 T5 T4 T3 TRH Temperature Conversion The DS1923’s temperature range begins at -20°C and ends at +85°C. Temperature values are represented as an 8-bit or 16-bit unsigned binary number with a resolu- tion of 0.5°C in 8-bit mode and 0.0625°C in 16-bit mode. The higher temperature byte TRH is always valid. In 16-bit mode, only the three highest bits of the lower byte TRL are valid. The five lower bits all read 0. TRL is undefined if the device is in 8-bit temperature mode. An out-of-range temperature reading is indicated as 00h or 0000h when too cold and FFh or FFE0h when too hot. With TRH and TRL representing the decimal equivalent of a temperature reading, the temperature value is cal- culated as: ϑ(°C) = TRH/2 - 41 + TRL/512 (16-bit mode, TLFS = 1, see address 0213h) ϑ(°C) = TRH/2 - 41 (8-bit mode, TLFS = 0, see address 0213h) This equation is valid for converting temperature read- ings stored in the data-log memory as well as for data read from the Latest Temperature Conversion Result register. To specify the temperature alarm thresholds, the previ- ous equations are resolved to: TALM = 2 x ϑ(°C) + 82 Because the temperature alarm threshold is only one byte, the resolution or temperature increment is limited to 0.5°C. The TALM value must be converted into hexadec- imal format before it can be written to one of the Temperature Alarm Threshold registers (Low Alarm address 0208h; High Alarm address 0209h). Independent of the conversion mode (8-bit or 16-bit), only the most significant byte of a temperature conver- sion is used to determine whether an alarm is generated. Humidity Conversion In addition to temperature, the DS1923 can log humidi- ty data in an 8-bit or 16-bit format. Humidity values are represented as 8-bit or 16-bit unsigned binary numbers with a resolution of 0.64%RH in the 8-bit mode and 0.04%RH in the 16-bit mode. The DS1923 reads data from its humidity sensor when- ever a Forced Conversion command is executed (see the Memory and Control Function Commands section) or during a mission if the device is set up to log humidi- ty data. Regardless of its setup, the DS1923 always reads 16 bits from the humidity sensor. The result of the latest humidity reading is found at address 020Eh (low byte) and 020Fh (high byte). The most significant bit read from the humidity sensor can always be found as H11 at address 020Fh. Due to the 12-bit digital output of the humidity sensor, the lower 4 bits in 16-bit format are undefined. Table 1. Temperature Conversion Examples TRH TRL MODE HEX DECIMAL HEX DECIMAL (°C) 8-Bit 54h 84 — — 1.0 8-Bit 17h 23 — — -29.5 16-Bit 54h 84 00h 0 1.000 16-Bit 17h 23 60h 96 -29.3125 Table 2. Temperature Alarm Threshold Examples TALM (°C) HEX DECIMAL 25.5 85h 133 -10.0 3Eh 62 |
|
Link URL |
| Does ALLDATASHEET help your business so far? [ DONATE ] |
About Alldatasheet | Advertisement | Contact us | Privacy Policy | Link to Datasheet | Link Exchange | Manufacturer List All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |