VP306 Datasheet(PDF) 26 Page - Mitel Networks Corporation |
|
|
|||||||||||||||||||||||||||||
VP306 Datasheet(HTML) 26 Page - Mitel Networks Corporation |
|
26 / 85 page ![]() VP305/6 DRAFT - PRELIMINARY DATA The duplication or disclosure of data contained on this sheet is subject to the restrictions on the title page of this document. 26 2.4. RADD: I²C Register address - Serial mode only. Not available on VP305. RADD is the I²C register address. It is the first byte written after the VP306 I²C chip address when in write mode. To write to the chip, the microprocessor should send a START condition and the chip address with the write bit set, followed by the register address where subsequent data bytes are to be written. Finally, when all the 'message' has been sent, a STOP condition is sent to free the bus. To read from the chip from register address one, the microprocessor should send a START condition and the chip address with the read bit set, followed by the requisite number of SCL clocks to read the bytes out. Finally a STOP condition is sent to free the bus. RADD is not sent in this case. To read from the chip from an address other than one, the microprocessor should send the chip address with the write bit set, followed by the register address where subsequent data bytes are to be read from. Then the microprocessor should send a START condition and the chip address with the read bit set, followed by the requisite number of SCL clocks to read the bytes out. Finally a STOP condition is sent to free the bus. This case should also be used to read the chip identification number in register zero. A STOP condition shall reset the RADD value to 01. For examples of use, see page 59. Serial mode - Address none. Type Write. 7654 3210 R/W IAI AD6 AD5 AD4 AD3 AD2 AD1 AD0 W AD[6:0] I²C register address, numbers in the range 0 to 63 are allowed. AD6 should be set to zero. IAI High = Inhibit auto increment. Low = Increment addresses. The IAI bit and function is only available via the I²C port. When the address is incremented to 63 it stops and the bus will continue to write to or read from 'register' 63 until a STOP condition is sent. Since 'register' 63 does not exist, data writen to it is lost or it will read back 255. |
|
Link URL |
| Does ALLDATASHEET help your business so far? [ DONATE ] |
About Alldatasheet | Advertisement | Contact us | Privacy Policy | Link to Datasheet | Link Exchange | Manufacturer List All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |