| Electronic Components Datasheet Search |
|
TDC-GP21 Datasheet(PDF) 86 Page - ams AG |
|
|
|||||||||||||||||||||||||||||
TDC-GP21 Datasheet(HTML) 86 Page - ams AG |
|
86 / 91 page ![]() TDC-GP21 acam messelectronic gmbh - Friedrich-List-Str.4 - 76297 Stutensee - Germany - www.acam.de 6-3 Register 5 ’h40000000 CON_FIRE = 2, enable FIRE_UP. If opcode Start_TOF_Restart is used FIRE_UP and FIRE_DOWN are used alternately for up and down flow measurements. With the configuration described here the measurement cycle starts sending fire pulses at pin FIRE_UP. EN_STARTNOISE = 0, switch off DIS_PHASESHIFT = 0, phase noise unit is active to improve the statistical behavior REPEAT_FIRE = 0, no sing-around PHFIRE = 0, no phase change in the fire pulse sequence ID5 = ’h00 Register 6 ’hC0E45000 EN_ANALOG = 1, use the internal analog circuit NEG_STOP_TEMP = 1, use the internal Schmitt trigger for the temperature measurement TW2 = 3, 300 µs delay to charge up the capacitors of the highpass EN_INT = b0101, interrupt given by Timeout TDC or ALU ready (see also register 2) START_CLKHS = 2, the ceramic oscillator has 480 µs to settle (see also register 0) CYCLE_TEMP = 0, use factor 1.0 for the Start_Temp_Restart CYCLE_TOF = 0, use factor 1.0 for the delay between two ToF measurements HZ60 = 0, 50 Hz base FIREO_DEF = 1, mandatory when using the internal analog circuit QUAD_RES = 0 DOUBLE_RES = 0, use 45 ps BIN TEMP_PORTDIR = 0, standard order for T measurement ANZ_FIRE = 10 (see register 0, too) ID6 = ’h00 (*) the contents of the registers can differ Measurement flow: Power-on reset: Send SO = ’h50 Load configuration from EEPROM to configuration registers: Send SO = ’hF0 Check-loop INTN = 0? for end of EEPROM action Calibrate Clock: Send SO = ’h03 Start_Cal_Resonator Check-loop INTN = 0? Send SO = ’hB0, Read SI = RES_0 Correction factor = 61.035/RES_0 Measurement loop: Temperature measurement, every 30 seconds: Send SO = ’h06 Start_Temp_Restart Check-loop INTN = 0? Send SO = ’hB4, Read SI = STAT STAT&’h0600 > 0: -> Error routine Send SO = ’h81314000 calculate HIT2- Start Wait for 2.8 μs (ALU time) Send SO = ’h81414000 calculate HIT3- Member of the ams Group |
|
Link URL |
| Does ALLDATASHEET help your business so far? [ DONATE ] |
About Alldatasheet | Advertisement | Contact us | Privacy Policy | Link to Datasheet | Link Exchange | Manufacturer List All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |