Back Button TDC-GP21 Datasheet HTML 83Page - ams AG TDC-GP21 Datasheet HTML 84Page - ams AG TDC-GP21 Datasheet HTML 85Page - ams AG TDC-GP21 Datasheet HTML 86Page - ams AG TDC-GP21 Datasheet HTML 87Page - ams AG TDC-GP21 Datasheet HTML 88Page - ams AG TDC-GP21 Datasheet HTML 89Page - ams AG TDC-GP21 Datasheet HTML 90Page - ams AG TDC-GP21 Datasheet HTML 91Page - ams AG  
Zoom Inzoom in Zoom Outzoom out
 89 / 91 page
background image
Ultrasonic-Flow-Converter
TDC-GP21
7-2
acam messelectronic gmbh - Friedrich-List-Str.4 - 76297 Stutensee - Germany - www.acam.de
7.1.3
Timeout Temperature Measurement
Note: Due to a bug it is necessary to have SEL_TIMO_MB2 at 2ms to get a correct
interrupt indication when 512 µs cycle time is selected.
7.1.4
Timeout TOF Measurement
Problem:
In case there is a timeout (e.g. because of air in the spool piece) the pulse -width
measurement starts but does not end before there is an INIT. The current is increased by
500 µA. The problem appears only with active pulse-width measurement.
Solutions:
1.
It is mandatory to answer to any interrupt from TDC-GP21 by minimum an INIT
command. Even in case you know the next data are bad you need to send an INIT to stop
the pulse-width measurement. Also in case you don’t read the data. Of course, timeout
has to be selected as an interrupt source.
7.2
Last Changes
27.05.2010 Target Specification, draft version
28.07.2010 Version 0.1 for release
13.08.2010 Version 0.2 slight changes
08.11.2010 Version 0.3 released
24.11.2010 Version 1.0 relesed, revision of section 4
17.01.2011 Version 1.1 released, several corrections in the whole document
08.02.2011 Version 1.1 small corrections in section 5 and 6.
21.02.2011 Version 1.1 slight corrections in section 3 and 5
03.03.2011 Version 1.2 released. Revision of the measurement flow example in section
6
05.08.2011 Version 1.3,new section 4.3.1 and 7.1. Reg5 corrected and further small
corrections
25.05.2012 Version 1.4 changes on pages 2-5; 3-7; 3-8; 3-10; 4-12; 6-2; 6-3
Member of the ams Group



Html Pages

1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55 56 57 58 59 60 61 62 63 64 65 66 67 68 69 70 71 72 73 74 75 76 77 78 79 80 81 82 83 84 85 86 87 88 89 90 91


Datasheet Download

Go To PDF Page


Link URL



Does ALLDATASHEET help your business so far?  [ DONATE ] 

About Alldatasheet   |   Advertisement   |   Contact us   |   Privacy Policy   |   Link to Datasheet    |   Link Exchange   |   Manufacturer List
All Rights Reserved©Alldatasheet.com


Mirror Sites
English : Alldatasheet.com  |   English : Alldatasheet.net  |   Chinese : Alldatasheetcn.com  |   German : Alldatasheetde.com  |   Japanese : Alldatasheet.jp
Russian : Alldatasheetru.com  |   Korean : Alldatasheet.co.kr  |   Spanish : Alldatasheet.es  |   French : Alldatasheet.fr  |   Italian : Alldatasheetit.com
Portuguese : Alldatasheetpt.com  |   Polish : Alldatasheet.pl  |   Vietnamese : Alldatasheet.vn
Indian : Alldatasheet.in  |   Mexican : Alldatasheet.com.mx  |   British : Alldatasheet.co.uk  |   New Zealand : Alldatasheet.co.nz
Family Site : ic2ic.com  |   icmetro.com