| Electronic Components Datasheet Search |
|
LPC47M182 Datasheet(PDF) 73 Page - SMSC Corporation |
|
|
|||||||||||||||||||||||||||||
LPC47M182 Datasheet(HTML) 73 Page - SMSC Corporation |
|
73 / 223 page ![]() Advanced I/O Controller with Motherboard GLUE Logic Datasheet SMSC LPC47M182 73 Revision 1.8 SMSC/Non-SMSC Register Sets (02-24-05) DATASHEET 6.20 Sense Drive Status Sense Drive Status obtains drive status information. It has not execution phase and goes directly to the result phase from the command phase. Status Register 3 contains the drive status information. 6.21 Specify The Specify command sets the initial values for each of the three internal times. The HUT (Head Unload Time) defines the time from the end of the execution phase of one of the read/write commands to the head unload state. The SRT (Step Rate Time) defines the time interval between adjacent step pulses. Note that the spacing between the first and second step pulses may be shorter than the remaining step pulses. The HLT (Head Load Time) defines the time between when the Head Load signal goes high and the read/write operation starts. The values change with the data rate speed selection and are documented in Table 6.26. The values are the same for MFM and FM. DMA operation is selected by the ND bit. When ND is “0”, the DMA mode is selected. This part does not support non-DMA mode. In DMA mode, data transfers are signaled by the DMA request cycles. 6.22 Configure The Configure command is issued to select the special features of the FDC. A Configure command need not be issued if the default values of the FDC meet the system requirements. Table 6.26 - Drive Control Delays (ms) HUT SRT 2M 1M 500K 300K 250K 2M 1M 500K 300K 250K 0 1 .. E F 64 4 .. 56 60 128 8 .. 112 120 256 16 .. 224 240 426 26.7 .. 373 400 512 32 .. 448 480 4 3.75 .. 0.5 0.25 8 7.5 .. 1 0.5 16 15 .. 2 1 26.7 25 .. 3.33 1.67 32 30 .. 4 2 HLT 2M 1M 500K 300K 250K 00 01 02 .. 7F 7F 64 0.5 1 .. 63 63.5 128 1 2 .. 126 127 256 2 4 .. 252 254 426 3.3 6.7 .. 420 423 512 4 8 . 504 508 6.22.1 Configure Default Values: EIS - No Implied Seeks EFIFO - FIFO Disabled POLL - Polling Enabled FIFOTHR - FIFO Threshold Set to 1 Byte PRETRK - Pre-Compensation Set to Track 0 EIS - Enable Implied Seek. When set to "1", the FDC will perform a Seek operation before executing a read or write command. Defaults to no implied seek. |
|
Link URL |
| Does ALLDATASHEET help your business so far? [ DONATE ] |
About Alldatasheet | Advertisement | Contact us | Privacy Policy | Link to Datasheet | Link Exchange | Manufacturer List All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |