39 / 52 page ![]() LT3752/LT3752-1 39 Rev. C For more information www.analog.com The selection of the main transformer will depend on the applications requirements : isolation voltage, power level, maximumvolt-seconds,turnsratio,componentsize,power losses and switching frequency. Transformerconstructionusingtheplanarwindingtechnol- ogy is typically chosen for minimizing leakage inductance and reducing component height. Transformer core type is usually a ferrite material for high frequency applications. Find a family of transformers that meet both the isolation and power level requirements of the application. The next step is to find a transformer within that family which is suitable for the application. The subsequent thought pro- cess for the transformer design will include : (1) Secondary turns (NS), core losses, temperature rise, flux density, switching frequency (2) Primary turns (NP), maximum duty cycle and reset voltages (3) Copper losses The expression for secondary turns (NS) is given by, NS = 108 VOUT/(fOSC • AC • BM) where, AC = cross-sectional area of the core in cm2 BM = maximum AC flux density desired For flux density, choose a level which achieves an accept- ablelevelofcoreloss/temperatureriseatagivenswitching frequency. The transformer data sheet will provide curves of core loss versus flux density at various switching fre- quencies.Thedatasheetwillalsoprovidetemperaturerise versus core loss. While choosing a value for BM to avoid excessive core losses will usually allow enough headroom for flux swing during input / load transients, still make sure to stay well below the saturation flux density of the transformer core. If needed, increasing NS will reduce flux density. After calculating NS, the number of primary turns (NP) can be calculated from, NP = NS • DMAX VIN(MIN)/VOUT where, VIN(MIN) = minimum system input voltage DMAX=maximumswitchdutycycleatVIN(MIN)(typically chosen between 0.6 and 0.7) At minimum input voltage the converter will run at a maxi- mum duty cycle DMAX. A higher transformer turns ratio (NP/NS) will create a higher DMAX but it will also require higher voltages at the drain of the primary side switch to resetthetransformer(seeprevioussectionsLosideActive ClampTopologyandHisideActiveClampTopology).DMAX values are typically chosen between 0.6 and 0.7. Even for a given DMAX value, the loop must also provide protection against duty cycles that may excessively exceed DMAX during transients or faults. While most converters only provide a fixed duty cycle clamp, the LT3752/LT3752-1 provideaprogrammablemaximumdutycycleclampDVSEC that also moves inversely with input voltage. The resulting function is that of a programmable volt- secondclamp.Thisallowstheusertochooseatransformer turns ratio for DMAX and then customize a maximum duty cycle clamp DVSEC above DMAX for safety. DVSEC then follows the natural duty cycle of the converter as a safety guardrail (see previous section Programming Duty Cycle Clamp). Afterdecidingontheparticulartransformerandturnsratio, the copper losses can then be approximated by, PCU = D • I(Load)(MAX)2 (RSEC + (NS/NP)2 RPRI) where, D = switch duty cycle (choose nominal 0.5) I(Load)(MAX) = maximum load current APPLICATIONS INFORMATION |
|
Link URL |
| Does ALLDATASHEET help your business so far? [ DONATE ] |
About Alldatasheet | Advertisement | Contact us | Privacy Policy | Link to Datasheet | Link Exchange | Manufacturer List All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |