Back Button ADU2 Datasheet HTML 69Page - List of Unclassifed Manufacturers ADU2 Datasheet HTML 70Page - List of Unclassifed Manufacturers ADU2 Datasheet HTML 71Page - List of Unclassifed Manufacturers ADU2 Datasheet HTML 72Page - List of Unclassifed Manufacturers ADU2 Datasheet HTML 73Page - List of Unclassifed Manufacturers ADU2 Datasheet HTML 74Page - List of Unclassifed Manufacturers ADU2 Datasheet HTML 75Page - List of Unclassifed Manufacturers ADU2 Datasheet HTML 76Page - List of Unclassifed Manufacturers ADU2 Datasheet HTML 77Page - List of Unclassifed Manufacturers Next Button
Zoom Inzoom in Zoom Outzoom out
 73 / 162 page
background image
Command Response Formats
Page 61
Table 5.8 lists the format for MBEN in ASCII:
Table 5.8: MBEN Data in ASCII
Variable
Description
Header
indicates the type of data sent and allows a resynchronization
with the data stream in case some bits were lost in
transmission. It reports in the receiver configuration.
($PASHR,MCA)
Structure identification
Sequence tag
the time tag used to associate all structures with one epoch. It is
in units of 50 ms and modulo 30 minutes (one count equals 50
ms and is reset every 30 minutes).
Number of remaining MBEN
structures
structures remaining to be sent for that epoch.
Satellite data
Satellite PRN number
PRN number for satellite in this message
Elevation
Satellite elevation angle in degrees. Values range from 0 to 90
degrees.
Azimuth
Satellite azimuth angle in degrees. Values range from 0 to 360
degrees.
Channel index
Internal ADU2 channel assignment (1 to 32)
Measurement data
Warning flag
Flag displaying status of receiver clock, carrier phase signal,
and loss of lock.
0 = everything OK
bit 1 set (1) = satellite range approaching 1 ms offset
bit 2 set (2) = clock offset is close to 1 ms
bit 3 set (4) = polarity known flag less than 5
bit 7 set (64)= receiver sometimes detects a false loss of lock.
This bit is used to flag this condition, but it is not set in the B-
file.
bit 8 set (128) = loss of lock in previous epoch
More than one bit may be set at the same time. For example, if
bits 1,2, and 3 are set at the same time, the warning flag will be
7 (1 + 2 + 4).



Html Pages

1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55 56 57 58 59 60 61 62 63 64 65 66 67 68 69 70 71 72 73 74 75 76 77 78 79 80 81 82 83 84 85 86 87 88 89 90 91 92 93 94 95 96 97 98 99 100  ...More


Datasheet Download

Go To PDF Page


Link URL



Does ALLDATASHEET help your business so far?  [ DONATE ] 

About Alldatasheet   |   Advertisement   |   Contact us   |   Privacy Policy   |   Link to Datasheet    |   Link Exchange   |   Manufacturer List
All Rights Reserved©Alldatasheet.com


Mirror Sites
English : Alldatasheet.com  |   English : Alldatasheet.net  |   Chinese : Alldatasheetcn.com  |   German : Alldatasheetde.com  |   Japanese : Alldatasheet.jp
Russian : Alldatasheetru.com  |   Korean : Alldatasheet.co.kr  |   Spanish : Alldatasheet.es  |   French : Alldatasheet.fr  |   Italian : Alldatasheetit.com
Portuguese : Alldatasheetpt.com  |   Polish : Alldatasheet.pl  |   Vietnamese : Alldatasheet.vn
Indian : Alldatasheet.in  |   Mexican : Alldatasheet.com.mx  |   British : Alldatasheet.co.uk  |   New Zealand : Alldatasheet.co.nz
Family Site : ic2ic.com  |   icmetro.com