| Electronic Components Datasheet Search |
|
TDP0604 Datasheet(PDF) 35 Page - Texas Instruments |
|
|
|
|||||||||||||||||||||||||||||
TDP0604 Datasheet(HTML) 35 Page - Texas Instruments |
|
35 / 65 page ![]() 8.4.2 DDC Snoop Feature As part of discovery the source reads the sink E-EDID information to understand the sink’s capabilities. Part of this read is HDMI Forum Vendor Specific Data Block (HF-VSDB) located at slave address 0xA8. From the LV_DDC_SDA and LV_DDC_SCL pins the TDP0604 DDC snoop function will monitor both reads and writes to TMDS Configuration at offset 20h of the Status and Control Data Channel Structure (SCDCS) located within the HF-VSDB. The DDC snoop function resides on the LV_DDC_SDA and LV_DDC_SCL pins. The TDP0604 has similar SCDCS registers within its register space. Through TDP0604 local I2C interface, external microprocessor can control TDP0604 to perform all the necessary functions required for each HDMI type. 8.4.2.1 HDMI Type The TDP0604 monitors offset 20h in order to determine HDMI type as either HDMI 1.4 or HDMI 2.0, as described in Table 8-16. Table 8-16. HDMI Type Selection HDMI Type TMDS_CLK_RATIO SCDCS Offset 20h[1] HDMI 1.4 (TMDS x10) 0 HDMI 2.0 (TMDS x40) 1 Note TDP0604 will default to HDMI 1.4 following a power-on reset or whenever it enters the powerdown state. Upon exiting standby, the TDP0604 will hold data rate value (HDMI 1.4 or 2.0) prior to entering the standby. 8.4.3 Low Power Modes The TDP0604 has two low power modes: Power Down and Standby. Both lower power modes are detailed in Table 8-17. Power down is entered when HPD_IN is low for tHPD_PWRDOWN or in I2C if PD_EN bit is set. Power down is also entered when the EN pin is low. The TDP0604 will exit power down to the standby state when HPD_IN is high for tHPD_STANDBY. The TDP0604 implements a two stage standby power process when HPD_IN is high. Stage 1: If there is no signal (electrical idle) on the IN_CLK lane, the TDP0604 will enter standby mode within tSTANDBY_ENTRY. Stage 2: If a signal is detected which last longer than tSIGDET_DB, then TDP0604 will declare a valid signal and exit standby within tSTANDY_EXIT. • If a signal is detected, the TDP0604 will go into normal active operation and signals present at IN_CLK and IN_D[2:0] inputs will be passed through to the OUT_CLK and OUT_D[2:0] outputs. • If it is determined that no signal is present, the TDP0604 will re-enter stage 1. The TDP0604 will exit normal operation and return to the standby state within tSTANDBY_ENTRY anytime the electrical idle is detected. www.ti.com TDP0604 SLLSFJ8 – DECEMBER 2021 Copyright © 2021 Texas Instruments Incorporated Submit Document Feedback 35 Product Folder Links: TDP0604 |
|
Link URL |
| Does ALLDATASHEET help your business so far? [ DONATE ] |
About Alldatasheet | Advertisement | Contact us | Privacy Policy | Link to Datasheet | Link Exchange | Manufacturer List All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |