| Electronic Components Datasheet Search |
|
TDP0604 Datasheet(PDF) 38 Page - Texas Instruments |
|
|
|
|||||||||||||||||||||||||||||
TDP0604 Datasheet(HTML) 38 Page - Texas Instruments |
|
38 / 65 page ![]() 4. The TDP0604 acknowledges the sub-address cycle. 5. The master presents the first byte of data to be written to the I2C register. 6. The TDP0604 acknowledges the byte transfer 7. The master may continue presenting additional bytes of data to be written, with each byte transfer completing with an acknowledge from the TDP0604. 8. The master terminates the write operation by generating a stop condition (P). A6 A5 A4 A3 A2 A1 A0 1 S D7 D6 D5 D4 D3 D2 D1 D0 A Slave Address A P Data from offset 0x00 or last read address + 1 Read Ack Start Stop Figure 8-12. I2C Read without repeated Start The following procedure should be followed to read the TDP0604 I2C registers without a repeated Start (refer to Figure 8-12). 1. The master initiates a read operation by generating a start condition (S), followed by the TDP0604 7-bit address and a zero-value “W/R” bit to indicate a read cycle. 2. The TDP0604 acknowledges the 7-bit address cycle. 3. Following the acknowledge the master continues sending clock. 4. The TDP0604 transmit the contents of the memory registers MSB-first starting at register 00h or last read register offset+1. If a write to the I2C register occurred prior to the read, then the TDP0604 shall start at the register offset specified in the write. 5. The TDP0604 waits for either an acknowledge (ACK) or a not-acknowledge (NACK) from the master after each byte transfer; the I2C master acknowledges reception of each data byte transfer. 6. If an ACK is received, the TDP0604 transmits the next byte of data as long as master provides the clock. If a NAK is received, the TDP0604 stops providing data and waits for a stop condition (P). 7. The master terminates the write operation by generating a stop condition (P). A6 A5 A4 A3 A2 A1 A0 0 S C7 C6 C5 C4 C3 C2 C1 C0 A Slave Address A Register Offset Xh Write Ack Start Sr Repeated Start A6 A5 A4 A3 A2 A1 A0 1 S D7 D6 D5 D4 D3 D2 D1 D0 A Slave Address A P Data from Register Xh Read Stop D7 D6 D5 D4 D3 D2 D1 D0 A Data from Register Xh + 1 Figure 8-13. I2C Read with repeated Start The following procedure should be followed to read the TDP0604 I2C registers with a repeated Start (refer to Figure 8-13). 1. The master initiates a read operation by generating a start condition (S), followed by the TDP0604 7-bit address and a zero-value “W/R” bit to indicate a write cycle. 2. The TDP0604 acknowledges the 7-bit address cycle. 3. The master presents the register offset within TDP0604 to be written, consisting of one byte of data, MSB-first. 4. The TDP0604 acknowledges the register offset cycle. 5. The master presents a repeated start condition (Sr). 6. The master initiates a read operation by generating a start condition (S), followed by the TDP0604 7-bit address and a one-value “W/R” bit to indicate a read cycle. 7. The TDP0604 acknowledges the 7-bit address cycle. 8. The TDP0604 transmit the contents of the memory registers MSB-first starting at the register offset. TDP0604 SLLSFJ8 – DECEMBER 2021 www.ti.com 38 Submit Document Feedback Copyright © 2021 Texas Instruments Incorporated Product Folder Links: TDP0604 |
|
Link URL |
| Does ALLDATASHEET help your business so far? [ DONATE ] |
About Alldatasheet | Advertisement | Contact us | Privacy Policy | Link to Datasheet | Link Exchange | Manufacturer List All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |