Back Button TLC6989 Datasheet HTML 13Page - Texas Instruments TLC6989 Datasheet HTML 14Page - Texas Instruments TLC6989 Datasheet HTML 15Page - Texas Instruments TLC6989 Datasheet HTML 16Page - Texas Instruments TLC6989 Datasheet HTML 17Page - Texas Instruments TLC6989 Datasheet HTML 18Page - Texas Instruments TLC6989 Datasheet HTML 19Page - Texas Instruments TLC6989 Datasheet HTML 20Page - Texas Instruments TLC6989 Datasheet HTML 21Page - Texas Instruments Next Button
Zoom Inzoom in Zoom Outzoom out
 17 / 72 page
background image
7.3.4.6.1 CHECK Bit Error
The CHECK (17th) bit of each CCSI data byte must be the NOT of the 16th bit. When the CHECK bit is the same
as the 16th bit, the FLAG_CCSI_CHECK_BIT, FLAG_CCSI, and FLAG_ERR are set to 1. The SPI controller
can access the TLC6989 and write 1 to CLR_FLAG to clear the flags. The CCSI peripheral stops receiving the
current CCSI command and waits until an END byte is received. Afterwards, the CCSI peripheral works normally
independent of the status of the error flags.
7.3.4.6.2 Data Integrity Diagnostics
Data that is transmitted by the CCSI controller which is not modified or extended within the daisy chain of LED
drivers is protected by the TLC6989 device with a CRC. Over all the transmitted words of the CCSI command a
CRC value is calculated. Once the command is received by the CCSI peripheral, another CRC is calculated over
all the received words. When the CRC over the transmitted words does not match the CRC over the received
words, the FLAG_CCSI_CRC, FLAG_CCSI, and FLAG_ERR are set to 1. The SPI controller can access the
TLC6989 and write 1 to CLR_FLAG to clear the flags.
When an SPI command starts with FWD (commands 0x2 to 0x7), the first data word of the SPI command
is checked. When this word matches a write FC0 to FC15 (0xAA00 to 0xAA0F) or VSYNC (0xAAF0) CCSI
command, the data integrity diagnostics is executed.
When this error flag is triggered consecutively, the CCSI controller and CCSI peripheral are likely out of
synchronization. In that case, TI recommends to perform a SOFTRESET command.
7.3.4.6.3 CCSI Command Queue Overflow
The TLC6989 provides a detection when there are too many commands in the queue to be transmitted by the
CCSI controller or expected to be received by the CCSI peripheral. When the command queue is full and a
new CCSI command is received by the SPI peripheral, the FLAG_CCSI_CMD_QUEUE_OVF, FLAG_CCSI, and
FLAG_ERR are set to 1. In addition, the CCSI command queue and TXFIFO are cleared in the same way as
TXFFCLR. The SPI controller can access the TLC6989 and write 1 to CLR_FLAG to clear the flags. The error
flag has to be cleared to be able to store new CCSI commands and the CCSI controller can start transmitting.
When the FLAG_CCSI_CMD_QUEUE_OVF is set, the CCSI controller and CCSI peripheral are likely to get out
of synchronization. Therefore, TI recommends to perform a SOFTRESET command after this flag has been set.
7.3.4.7 FIFO Diagnostics
Both the TXFIFO and RXFIFO have their own overflow and underflow diagnostics. Below sections decribe these
in more detail.
7.3.4.7.1 TXFIFO Overflow
When the TXFIFO is full (TXFFST = 0x1FF) and new data words are received by the SPI peripheral which have
to be stored in the TXFIFO, the FLAG_TXFFOVF, FLAG_TXFF, and FLAG_ERR are set to 1. In addition, the
TXFIFO is cleared in the same way as TXFFCLR. The SPI controller can access the TLC6989 and write 1 to
CLR_FLAG to clear the flags. The error flag has to be cleared to be able to store new CCSI data words on the
TXFIFO and the CCSI controller can start transmitting.
7.3.4.7.2 TXFIFO Underflow
When the FIFO is empty (TXFFST = 0x0) and the CCSI controller tries to read a new word from the TXFIFO, the
FLAG_TXFFUVF, FLAG_TXFF, and FLAG_ERR are set to 1. The ongoing transmission by the CCSI controller
is stopped. The SPI controller can access the TLC6989 and write 1 to CLR_FLAG to clear the flags. The error
flag has to be cleared to be able to store new CCSI data words on the TXFIFO and the CCSI controller can start
transmitting.
7.3.4.7.3 TXFIFO Single Error Detection (SED)
The TXFIFO is protected with a parity bit. When a single bit error is detected during a read operation from the
TXFIFO, the FLAG_TXFFSED, FLAG_TXFF, and FLAG_ERR are set to 1. The ongoing transmission by the
CCSI controller is stopped. However, the TXFIFO is not automatically cleared. The SPI controller can access the
www.ti.com
TLC6989
SLVSHF5 – NOVEMBER 2024
Copyright © 2024 Texas Instruments Incorporated
Submit Document Feedback
17
Product Folder Links: TLC6989



Html Pages

1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55 56 57 58 59 60 61 62 63 64 65 66 67 68 69 70 71 72


Datasheet Download

Go To PDF Page


Link URL



Does ALLDATASHEET help your business so far?  [ DONATE ] 

About Alldatasheet   |   Advertisement   |   Contact us   |   Privacy Policy   |   Link to Datasheet    |   Link Exchange   |   Manufacturer List
All Rights Reserved©Alldatasheet.com


Mirror Sites
English : Alldatasheet.com  |   English : Alldatasheet.net  |   Chinese : Alldatasheetcn.com  |   German : Alldatasheetde.com  |   Japanese : Alldatasheet.jp
Russian : Alldatasheetru.com  |   Korean : Alldatasheet.co.kr  |   Spanish : Alldatasheet.es  |   French : Alldatasheet.fr  |   Italian : Alldatasheetit.com
Portuguese : Alldatasheetpt.com  |   Polish : Alldatasheet.pl  |   Vietnamese : Alldatasheet.vn
Indian : Alldatasheet.in  |   Mexican : Alldatasheet.com.mx  |   British : Alldatasheet.co.uk  |   New Zealand : Alldatasheet.co.nz
Family Site : ic2ic.com  |   icmetro.com