Back Button ADF4378 Datasheet HTML 36Page - Analog Devices ADF4378 Datasheet HTML 37Page - Analog Devices ADF4378 Datasheet HTML 38Page - Analog Devices ADF4378 Datasheet HTML 39Page - Analog Devices ADF4378 Datasheet HTML 40Page - Analog Devices ADF4378 Datasheet HTML 41Page - Analog Devices ADF4378 Datasheet HTML 42Page - Analog Devices ADF4378 Datasheet HTML 43Page - Analog Devices ADF4378 Datasheet HTML 44Page - Analog Devices Next Button
Zoom Inzoom in Zoom Outzoom out
 40 / 84 page
background image
Data Sheet
ADF4378
APPLICATIONS INFORMATION
analog.com
Rev. A | 40 of 84
SYSREF Output Settings
The retimed SYSREF output is available as LVDS compatible
signal on the SR_OUTP and SR_OUTN pins. SYSREF output
can be powered down by either setting the ENSR pin LOW or
programming PD_SYSOUT bit in Register 0x001A to 1.
A 7-bit delay, SR_DEL, may be used to increase time delay be-
tween rising edge of CLK and SYSREF signal. SR_DEL[6:0] in
REG0043 is used to set the delay. With INV_SR in REG0043 = 0,
the SYSREF aligns with a clock rising edge. The retiming edge may
be inverted, which also has the effect of adding an additional 0.5 ×
tCLK of delay. To enable this, set INV_SR in REG0043 = 1.
Table 33. SPI Summary, SYSREF OUTPUT Settings
Bit Field
Value
PD_SYSOUT
0x00
SR_DEL[0:6]
0x00 to 0x7F
INV_SR
0x00 (default), 0x01 for additional 0.5 × tCLK delay
Double Buffer and Manual VCO Calibration
Settings
If multiple frequency settings are required, double buffering (for
more information, see the Double Buffering section) and manual
programming of the VCO settings can improve frequency switching
times. In a single fixed frequency application, such as this design
procedure, these modes are rarely required. Therefore, related bits
can remain in their power-up default state.
Table 34. SPI Summary, Double Buffer and Manual VCO Calibration Settings
Bit Field
Value
M_VCO_CORE
0x0
M_VCO_BAND
0x0
M_VCO_BIAS
0x0
O_VCO_CORE
0x0
O_VCO_BAND
0x0
O_VCO_BIAS
0x0
CLKO_DIV_DB
0x0
DCLK_DIV_DB
0x0
O_VCO_DB
0x0
DEL_CTRL_DB
0x0
SPI Protocol Settings
The design goals stated for the SPI protocol (for more information,
see the Serial Port section) are 1.8 V logic, 4-wire SPI, and
optimize SPI write sequence. REG0000, REG0001, and REG0018
have the SPI related register bits, which are shown in Table 35 with
the required state based on the design goals. The power-on default
state is assumed if the bit function is not listed as a design goal.
Table 35. SPI Summary - SPI Protocol
Bit Field
Value
CMOS_OV
0x0
SDO_ACTIVE, SDO_ACTIVE_R
0x1
ADDRESS_ASCENSION, AD-
DRESS_ASCENSION_R
0x0
SINGLE_INSTRUCTION
0x0
LSB_FIRST, LSB_FIRST_R
0x0
MAIN_READBACK_CONTROL
0x0
Remaining Register Settings
The Charge-Pump Test Mode , MUXOUT, and Block Power-Down
Control sections list several bit fields that are recommended for
special purposes, such as debug or ambient die temperature meas-
urements. For this normal use case, these bit fields must be set to
their POR state (see Table 36). SOFT_RESET, SOFT_RESET_R,
RST_SYS, and ADC_ST_CNV are the only remaining RW bit fields
not shown yet, and must also be set to their POR state (see Table
36).
The bit columns in Table 44 have several cells without a name.
These unnamed, reserved cells must be programmed to the state
provided in Table 44 for proper operation.
Table 36. SPI Summary, Remaining Registers
Bit Field
Value
EN_CPTEST
0x0
CP_UP
0x0
CP_DOWN
0x0
MUXOUT
0x0
PD_CLK
0x0
PD_CALDAC
0x0
PD_ALL
0x0
PD_RDIV
0x0
PD_NDIV
0x0
PD_VCO
0x0
PD_LD
0x0
PD_PFDCP
0x0
SOFT_RESET, SOFT_RESET_R
0x0
RESET_SYS
0x0
ADC_ST_CNV
0x0
Programming Procedure
There are two different methods to power up the ADF4378. The
most commonly used method provided in the Standard Power-Up
and Initialization Sequence, Automatic VCO Calibration section is
mandatory on the initial device power-up.



Html Pages

1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55 56 57 58 59 60 61 62 63 64 65 66 67 68 69 70 71 72 73 74 75 76 77 78 79 80 81 82 83 84


Datasheet Download

Go To PDF Page


Link URL



Does ALLDATASHEET help your business so far?  [ DONATE ] 

About Alldatasheet   |   Advertisement   |   Contact us   |   Privacy Policy   |   Link to Datasheet    |   Link Exchange   |   Manufacturer List
All Rights Reserved©Alldatasheet.com


Mirror Sites
English : Alldatasheet.com  |   English : Alldatasheet.net  |   Chinese : Alldatasheetcn.com  |   German : Alldatasheetde.com  |   Japanese : Alldatasheet.jp
Russian : Alldatasheetru.com  |   Korean : Alldatasheet.co.kr  |   Spanish : Alldatasheet.es  |   French : Alldatasheet.fr  |   Italian : Alldatasheetit.com
Portuguese : Alldatasheetpt.com  |   Polish : Alldatasheet.pl  |   Vietnamese : Alldatasheet.vn
Indian : Alldatasheet.in  |   Mexican : Alldatasheet.com.mx  |   British : Alldatasheet.co.uk  |   New Zealand : Alldatasheet.co.nz
Family Site : ic2ic.com  |   icmetro.com