| Electronic Components Datasheet Search |
|
LTC2972 Datasheet(PDF) 76 Page - Linear Technology |
|
|
|||||||||||||||||||||||||||||
LTC2972 Datasheet(HTML) 76 Page - Linear Technology |
|
76 / 112 page ![]() LTC2972 76 2972fa For more information www.linear.com/LTC2972 READ_IOUT This command returns the most recent ADC measured value of the channel’s output current. MFR_IIN_PEAK This command returns the maximum ADC measured value of the input current. This register is reset to 0x7C00 (–225) when the LTC2972 emerges from power-on reset, when a CLEAR_FAULTS command to any page is executed, or a channel goes through an off-to-on transition. MFR_IIN_MIN This command returns the minimum ADC measured value of the input current. This register is reset to 0x7BFF (ap- proximately 225) when the LTC2972 emerges from power-on reset, when a CLEAR_FAULTS command to any page is executed, or a channel goes through an off-to-on transition. MFR_PIN_PEAK This command returns the maximum ADC measured value of the input power. This register is reset to 0x7C00 (–225) when the LTC2972 emerges from power-on reset, when a CLEAR_FAULTS command to any page is executed, or a channel goes through an off-to-on transition. MFR_PIN_MIN This command returns the minimum ADC measured value of the input power. This register is reset to 0x7BFF (ap- proximately 225) when the LTC2972 emerges from power-on reset, when a CLEAR_FAULTS command to any page is executed, or a channel goes through an off-to-on transition. READ_TEMPERATURE_1 This command returns the most recent measured value of the external diode temperature in °C. This value is used for all temperature related operations and calculations. This command is paged. READ_TEMPERATURE_2 is substituted for READ_TEMPERATURE_1 if the associated TSENSE network fails to detect a valid temperature. The TSENSE network will fail to detect a valid temperature under the following conditions: The TSENSE pin is shorted to a constant voltage. The sense diode has an ideality factor greater than N_TS max. Floating the TSENSE pin is not recommended and may return unpredictable temperature values. READ_TEMPERATURE_2 This command returns the most recent ADC measured value of junction temperature in °C as determined by the LTC2972’s internal temperature sensor. This register is for information purposes and does not generate any faults, warnings, or affect any other registers or internal calculations unless it is used as READ_TEMPERATURE_1. This command is not paged. READ_TEMPERATURE_2 is substituted for READ_TEMPERATURE_1 if a channel’s TSENSE network fails to detect a valid temperature. PMBus COMMAND DESCRIPTION |
|
Link URL |
| Does ALLDATASHEET help your business so far? [ DONATE ] |
About Alldatasheet | Advertisement | Contact us | Privacy Policy | Link to Datasheet | Link Exchange | Manufacturer List All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |