39 / 112 page ![]() LTC2972 39 2972fa For more information www.linear.com/LTC2972 MFR_CONFIG_LTC2972 Data Contents BIT(S) SYMBOL OPERATION b[15] Mfr_config_track_en Select if channel is a slave in a tracked power supply system. 0: Channel is not a slave in a tracked power supply system. 1: Channel is a slave in a tracked power supply system. Setting this bit disables UV detection during TOFF_DELAY. b[14] Mfr_config_cascade_on Configures channel’s control pin for cascade sequence ON. There is no provision for cascade sequence OFF. See description for time based sequence OFF options. b[13:12] Mfr_config_controln_sel Selects the active control pin input (CONTROL0 , CONTROL1) for this channel. 00: Select CONTROL0 pin. 01: Select CONTROL1 pin. 10: Reserved. 11: Reserved. b[11] Mfr_config_fast_servo_off Disables fast servo when margining or trimming output voltages: 0: fast-servo enabled. 1: fast-servo disabled. b[10] Mfr_config_supervisor_resolution Selects voltage supervisor resolution: 0: high resolution = 4mV/LSB, range for VVSENSEPn – VVSENSEMn is 0 to 3.8V 1: low resolution = 8mV/LSB, range for VVSENSEPn – VVSENSEMn is 0 to 6.0V b[9] Reserved Always returns 0. b[8] Mfr_config_imon_sel Select input range of Current Sense Channel: 0: DCR Sense telemetry mode, Range for VISENSEPn – VISENSEMn is –170mV to +170mV 1: Buffered IMON telemetry mode, Range for VISENSEPn – VISENSEMn is –0.1V to 6.0V b[7] Mfr_config_servo_continuous Select whether the UNIT should continuously servo VOUT after it has reached a new margin or nominal target. Only applies when Mfr_config_dac_mode = 00b. 0: Do not continuously servo VOUT after reaching initial target. 1: Continuously servo VOUT to target. b[6] Mfr_config_servo_on_warn Control re-servo on warning feature. Only applies when Mfr_config_dac_mode = 00b and Mfr_config_ servo_continuous = 0. 0: Do not allow the unit to re-servo when a VOUT warning threshold is met or exceeded. 1: Allow the unit to re-servo VOUT to nominal target if VOUT ≥ V(Vout_ov_warn_limit) or VOUT ≤ V(Vout_uv_warn_limit). b[5:4] Mfr_config_dac_mode Determines how DAC is used when channel is in the ON state and TON_RISE has elapsed. 00: Soft-connect (if needed) and servo to target. 01: DAC not connected. 10: DAC connected immediately using value from MFR_DAC command. If this is the configuration after a reset or RESTORE_USER_ALL, The value in MFR_DAC_STARTUP will be used to set the DAC output. 11: DAC is soft-connected. After soft-connect is complete MFR_DAC may be written. b[3] Reserved Always set to 1. b[2] Mfr_config_vo_en_wpd_en VOUT_EN current-limited pull-down enable. 0: Use a fast N-channel device to pull down VOUT_EN pin when the channel is off for any reason. 1: Use weak current-limited pull-down to discharge VOUT_EN pin when channel is off due to soft stop by the CONTROL pin and/or OPERATION command. If the channel is off due to a fault, use the fast pull-down on the VOUT_EN pin. PMBus COMMAND DESCRIPTION |
|
Link URL |
| Does ALLDATASHEET help your business so far? [ DONATE ] |
About Alldatasheet | Advertisement | Contact us | Privacy Policy | Link to Datasheet | Link Exchange | Manufacturer List All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |