| Electronic Components Datasheet Search |
|
FXLS8964AF Datasheet(PDF) 57 Page - NXP Semiconductors |
|
|
|||||||||||||||||||||||||||||
FXLS8964AF Datasheet(HTML) 57 Page - NXP Semiconductors |
|
57 / 98 page ![]() NXP Semiconductors FXLS8964AF 3-Axis Low-g Accelerometer FXLS8964AF All information provided in this document is subject to legal disclaimers. © NXP B.V. 2020. All rights reserved. Objective data sheet Rev. 2 — 30 October 2020 57 / 98 Note: High-Z means high impedance condition, with the state of the INTx pin defined by the external pull-up or pull-down resistor. Table 57. INTx pin behavior as a function of INT_PP_OD and INT_POL bit settings (valid only when BT_MODE = VDD) INTx pin configuration INT_PP_OD INT_POL INTx pin asserted value INTx pin deasserted value External pull-up resistor added (open-drain) X X 0 1 13.15 SENS_CONFIG5 register (address 19h) Table 58. SENS_CONFIG5 register (address 19h) bit allocation Bit 7 6 5 4 3 2 1 0 Name — — — VECM_ EN X_DIS Y_DIS Z_DIS HIBERNATE_ EN Reset (BT_MODE = GND) 0 0 0 0 0 0 0 0 Reset (BT_MODE = VDD) 0 0 0 0 0 0 0 0 Access R/W R/W R/W R/W R/W R/W R/W R/W Table 59. SENS_CONFIG5 register (address 19h) bit description Field Description 4 VECM_EN Vector Magnitude calculation enable: 0 (default): 12-bit vector magnitude result is not calculated on every ODR cycle. The VECM_LSB and VECM_MSB registers are not included in auto-increment address range. 1: 12-bit vector magnitude result is calculated on every ODR cycle. The VECM_LSB and VECM_MSB registers are included in auto-increment address range. Note: The vector magnitude result may also be used as an input to the SDCD function when SDCD_ CONFIG2[MODE] = 1. 3 X_DIS X-axis auto-increment disable: 0 (default): X-axis measurement is included in the auto-increment address range for both buffered and non-buffered modes (default). 1: X-axis measurement is excluded from the auto-increment address range. 2 Y_DIS Y-axis auto-increment disable: 0 (default): Y-axis measurement is included in the auto-increment address range for both buffered and non-buffered modes (default). 1: Y-axis measurement is excluded from the auto-increment address range. 1 Z_DIS Z-axis auto-increment disable: 0 (default): Z-axis measurement is included in the auto-increment address range for both buffered and non-buffered modes (default). 1: Z-axis measurement is excluded from the auto-increment address range. |
|
Link URL |
| Does ALLDATASHEET help your business so far? [ DONATE ] |
About Alldatasheet | Advertisement | Contact us | Privacy Policy | Link to Datasheet | Link Exchange | Manufacturer List All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |