| Electronic Components Datasheet Search |
|
MP5990 Datasheet(PDF) 22 Page - Monolithic Power Systems |
|
|
|||||||||||||||||||||||||||||
MP5990 Datasheet(HTML) 22 Page - Monolithic Power Systems |
|
22 / 72 page ![]() MP5990 – 16V, 50A, 1mΩ, INTELLIGENT HOT-SWAP SOLUTION WITH PMBUS MP5990 Rev. 1.1 MonolithicPower.com 22 4/19/2024 MPS Proprietary Information. Patent Protected. Unauthorized Photocopy and Duplication Prohibited. © 2024 MPS. All Rights Reserved. The MP5990 can operate in parallel with multiple MP5991s or other devices for high- current applications. The current-balance loop balances the start-up current for each active channel. Connect the IMON pins of all devices together for current balancing. The sensed current from each active IMON pin is summed, then divided by the number of active channels. The resulting average load current (ILOAD) provides a value for the total ILOAD. Start-up current balancing is essential to achieve the thermal advantages of parallel operation. Current sharing/balancing can aid power loss by dissipating the heat across the devices and the large area. The MP5991 ’s current balance is achieved by comparing the sensed CS current (ICS) of each device to the average current. This creates an appropriate VGATE adjustment for each Intelli- Fuse during start-up. The equivalent average RIMON (RIMON_AVG) can be calculated with Equation (6): RIMON_AVG = RCS / N (6) Where N is the number of active devices. Over-Current Limit Reference (OCREF) The OCREF pin is a DAC output that sets the over-current reference (VOCREF), which can be configured to be between 0V and 1.76V via register OC_REF (C6h). The MP5990 ’s ILOAD is limited by VOCREF and the external current-sense resistor (RCS). To regulate VGATE, VCS is compared to VOCREF through an amplifier. This prevents the Intelli- Fuse current from exceeding the current limit set by VOCREF. To protect the MP5990 from overheating during start-up, the OCREF pin has an internal clamp voltage (VOCREF_CLAMP) that depends on VIN and VOUT (see Figure 6). If VOUT is below 80% of VIN, then VOCREF_CLAMP is VBE (about 635mV with a negative temperature coefficient). If VOUT exceeds 80% of VIN, then VOCREF_CLAMP is released to 2V. 80% of VIN 2V VOCREF_CLAMP 0V VOUT 0V t VBE Figure 6: OCREF Internal Clamp Voltage If VOCREF is below VOCREF_CLAMP, the actual current-limit reference voltage is determined by VOCREF. If VOCREF exceeds VOCREF_CLAMP, the actual current-limit reference voltage is determined by VOCREF_CLAMP. Over-Current Protection (OCP) The MP5990 provides two types of OCP: VIMON- based total OCP and VCS-based OCP on the Intelli-Fuse. In multi-phase applications, Intelli-Fuse OCP can set the per-phase OCP limit. The total OCP limit can set the system ’s total OC limit. The Intelli-Fuse over-current limit (ILIMIT) is a function of the CS resistor (RCS), current-sense gain (GCS), and VOCREF. ILIMIT can be calculated with Equation (7): OCREF LIMIT CS CS V I = GR (7) The MP5990 ’s current limit can exceed the normal maximum load current, allowing for tolerances in the current-sense value. Intelli-Fuse OCP during Start-Up If VCS exceeds VOCREF during SS, VGATE is regulated to maintain a constant IFET. If VOUT is below 1/8 of VIN and the MOSFET current is regulated by VOCREF for 2.1ms, then the MOSFET turns off as a faulty latch condition and GOK is pulled low (see Figure 7 on page 23). |
|
Link URL |
| Does ALLDATASHEET help your business so far? [ DONATE ] |
About Alldatasheet | Advertisement | Contact us | Privacy Policy | Link to Datasheet | Link Exchange | Manufacturer List All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |