Back Button AD5753 Datasheet HTML 41Page - Analog Devices AD5753 Datasheet HTML 42Page - Analog Devices AD5753 Datasheet HTML 43Page - Analog Devices AD5753 Datasheet HTML 44Page - Analog Devices AD5753 Datasheet HTML 45Page - Analog Devices AD5753 Datasheet HTML 46Page - Analog Devices AD5753 Datasheet HTML 47Page - Analog Devices AD5753 Datasheet HTML 48Page - Analog Devices AD5753 Datasheet HTML 49Page - Analog Devices Next Button
Zoom Inzoom in Zoom Outzoom out
 45 / 72 page
background image
Data Sheet
AD5753
Rev. 0 | Page 45 of 72
ADC Configuration
The ADC is configured using the ADC_CONFIG register via the
SEQUENCE_COMMAND bits (Bits[10:8]), the SEQUENCE_
DATA bits (Bits[7:5]), and the ADC_IP_SELECT bits (Bits[4:0]).
Table 19 shows the contents of the ADC_CONFIG register.
Table 19. ADC Configuration Register
[D10:D8]
[D7:D5]
[D4:D0]
Command
Data
ADC input select
The ADC can be set up to either monitor a single node of interest
or configured to sequence through up to eight nodes of interest.
The sequential conversions can be initiated automatically after
every valid SPI frame is received by the device (automatic sequence
mode), or in a more controlled manner via a specific key code
written to the key register (key sequence mode). When a
conversion is complete, the ADC result is available in the status
register and, if in sequence mode, the sequencer address is
advanced. If autostatus readback mode is used in conjunction with
either sequence mode, the last completed ADC conversion data is
available on the SDO during every SPI frame written to the device.
The sequencer command has a maximum channel depth of
eight channels. Each channel in the sequencer must be configured
with the required ADC input for that sequencer channel via the
ADC_IP_SELECT bits. The number of configured channels must
equal the channel depth. If the active sequencer channel location is
not configured correctly, the sequencer stores the previously
loaded channel value and defaults all other enabled sequencer
channels 0b00000 for all sequencer channels. To avoid any 3-wire
interface related delays between ADC conversions if a dc-to-dc die
node is required to be part of the ADC sequencer, perform this
configuration using the DCDC_ADC_CONTROL_DIAG bits in
the DCDC_CONFIG2 register before configuring the ADC
sequencer. If multiple nodes from the dc-to-dc die are required
within the sequence, key sequencing mode must be used rather
than automatic sequencing mode because the DCDC_ADC_
CONTROL_DIAG bits must be updated between ADC
conversions to configure the next dc-to-dc die node required by the
sequence.
The four ADC modes of operation are key sequencing,
automatic sequencing, single immediate conversion, and single
key conversion. The sequencing modes are mutually exclusive so if
the key sequencing mode is enabled, it disables the automatic
sequencing mode and vice versa.
Key Sequencing (Command 010)
Writing Command 010 to the command bits in the ADC_
CONFIG register enables key sequencing mode. Key sequencing
starts with a write to the key register with Key Code 0x1 ADC and
starts on Channel 0, continuing to Channel N – 1, where N is
the channel depth with every 0x1ADC command. This mode
enables users to control channel switching during sequencing
because the switch only occurs every specific key code command,
rather than for every valid SPI frame, which occurs in
automatic sequencing mode. When the sequence is completed,
it starts again with Channel 0 until disabled. Before Command
0b010 is issued, Command 000 and Command 001 must be used
to configure all the required channels to enable key sequencing
mode (see Figure 86). If the sequencing is disabled and later
reenabled, the sequencer is reset to recommence converting on
the first channel in the sequence.
Automatic Sequencing (Command 011)
Sequencing starts on the next valid SPI frame and starts with
Channel 0, continuing to Channel N − 1 where N is the channel
depth on every valid SPI frame. When the sequence is complete, it
starts again with Channel 0 until disabled. As with the key
sequencing mode, before Command 011 is issued, Command 000
and Command 001 must be used to configure all the required
channels to enable automatic sequencing mode (see Figure 86). If
the sequencing is disabled and later reenabled, the sequencer is
reset to recommence converting on the first channel in the
sequence. When reenabled, the channels do not need to be
reconfigured unless the desired list of nodes changes. Use
automatic sequencing in conjunction with the autostatus
readback mode to ensure that the latest ADC result is available.
Single Immediate Conversion (Command 100)
Single immediate conversion mode initiates a single conversion
on the node currently selected in the ADC_IP_SELECT bits of the
ADC_CONFIG register. Selecting this command stops any active
automatic sequence, which means the sequencer must be reenabled
if required. The sequencer does not need to be reconfigured
because the configuration of the sequencer depth and channels
is stored.
Single Key Conversion (Command 101)
Single key conversion mode sets up an individual ADC input
node to be converted when the user initiates the mode by
writing the 0x1ADC key code to the key register.
Sequencing Mode Setup
A list of the relevant ADC sequencer commands are shown in
Table 20. These commands are available in the ADC_CONFIG
register; see Table 44 for the ADC_CONFIG register bits. The
default depth (000) is equivalent to one diagnostic channel up to a
binary depth value of 111, which is equivalent to eight channels.
Table 20. Command Bits
Value
Description
000
Set the sequencer depth (0 to 7)
001
Load the sequencer Channel N with the selected ADC
input
010
Enable or disable key sequencer
011
Enable or disable automatic sequencer
100
Perform a single conversion on the currently selected
ADC input
101
Set up single key conversion, that is, select the ADC mux
input to be used when the 0x1ADC key is written with a
write to the key register (this conversion is outside of the
key sequencing mode)



Html Pages

1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55 56 57 58 59 60 61 62 63 64 65 66 67 68 69 70 71 72


Datasheet Download

Go To PDF Page


Link URL



Does ALLDATASHEET help your business so far?  [ DONATE ] 

About Alldatasheet   |   Advertisement   |   Contact us   |   Privacy Policy   |   Link to Datasheet    |   Link Exchange   |   Manufacturer List
All Rights Reserved©Alldatasheet.com


Mirror Sites
English : Alldatasheet.com  |   English : Alldatasheet.net  |   Chinese : Alldatasheetcn.com  |   German : Alldatasheetde.com  |   Japanese : Alldatasheet.jp
Russian : Alldatasheetru.com  |   Korean : Alldatasheet.co.kr  |   Spanish : Alldatasheet.es  |   French : Alldatasheet.fr  |   Italian : Alldatasheetit.com
Portuguese : Alldatasheetpt.com  |   Polish : Alldatasheet.pl  |   Vietnamese : Alldatasheet.vn
Indian : Alldatasheet.in  |   Mexican : Alldatasheet.com.mx  |   British : Alldatasheet.co.uk  |   New Zealand : Alldatasheet.co.nz
Family Site : ic2ic.com  |   icmetro.com