124 / 144 page

CP320-IO1 Module
CP321
Page A - 14
© 2003 Kontron Modular Computers GmbH
ID 24977, Rev. 02
A.8. Jumper Setting
The jumper settings of the IO1 module depend on the module’s position relative to the CP321
and other modules, if any (please see Figure A4 below).
Figure A-5: Cascading of IO1 (or other) Modules onto the CP321
Table A-5: IO1 Jumper Settings for Different Module Positions
POSITION
IDSEL
CLOCK
GNT#
REQ#
J12
J11
J10
J1
J2
J3
J4
J5
J6
J7
J8
J9
P1
Set
Open
Open
Set
Open
Open
Set
Open
Open
Set
Open
Open
P2
Open
Set
Open
Open
Set
Open
Open
Set
Open
Open
Set
Open
Note...
Position P1 refers to the settings applicable for a module attatched to
the CP321 in position P1.
Position P2 refers to the settings applicable for a module attatched to
the CP321 in position P2.
KEY
P1: 1 additional module
P2: 2 additional modules
P1
P2
AB
RS T
LNK.
SPEE D
ACT.
W
UH