74 / 144 page

Configuration
CP321
Page 4 - 16
© 2003 Kontron Modular Computers GmbH
ID 24977, Rev. 02
4.4
UART Registers Address Mapping
4.4.1
UART A
The following table indicate the address mapping of the UART A. For a more detailed descrip-
tion please refer to the EXAR XR16C2850 DUART manual.
Table 4-15:UART A General Register Set
READ MODE
WRITE MODE
ADDRESS
Receive Holding Register
Transmit Holding Register
0xFFE0 0000
n/a
Interrupt Enable Register
0xFFE0 0001
Interrupt Status Register
FIFO Control Register
0xFFE0 0002
n/a
Line Control Register
0xFFE0 0007
n/a
Modem Control Register
0xFFE0 0004
Line Status Register
n/a
0xFFE0 0005
Modem Status Register
n/a
0xFFE0 0006
Scratchpad Register
Scratchpad Register
0xFFE0 0007
Table 4-16:UART A Baud Rate Register Set
READ MODE
WRITE MODE
ADDRESS
LSB of divisor latch
LSB of divisor latch
0xFFE0 0000
MSB of divisor latch
MSB of divisor latch
0xFFE0 0001
Table 4-17:UART A Enhanced Register Set
READ MODE
WRITE MODE
ADDRESS
Trigger Level Register
Trigger Level Register
0xFFE0 0000
Feature Control Register
Feature Control Register
0xFFE0 0001
Enhanced Feature Register
Enhanced Feature Register
0xFFE0 0002
Enhanced Mode Select Register
Enhanced Mode Select Register
0xFFE0 0007
Xon-1
Xon-1
0xFFE0 0004
Xon-2
Xon-2
0xFFE0 0005
Xoff-1
Xoff-1
0xFFE0 0006
Xoff-2
Xoff-2
0xFFE0 0007