Back Button ST7571 Datasheet HTML 39Page - Sitronix Technology Co., Ltd. ST7571 Datasheet HTML 40Page - Sitronix Technology Co., Ltd. ST7571 Datasheet HTML 41Page - Sitronix Technology Co., Ltd. ST7571 Datasheet HTML 42Page - Sitronix Technology Co., Ltd. ST7571 Datasheet HTML 43Page - Sitronix Technology Co., Ltd. ST7571 Datasheet HTML 44Page - Sitronix Technology Co., Ltd. ST7571 Datasheet HTML 45Page - Sitronix Technology Co., Ltd. ST7571 Datasheet HTML 46Page - Sitronix Technology Co., Ltd. ST7571 Datasheet HTML 47Page - Sitronix Technology Co., Ltd. Next Button
Zoom Inzoom in Zoom Outzoom out
 43 / 76 page
background image
ST7571
Ver 1.5a
43/76
2009/7/21
9.1.19 Set COM Scan Direction
This instruction selects the COM output scanning direction and determines the LCD driver output status.
A0
R/W
DB7
DB6
DB5
DB4
DB3
DB2
DB1
DB0
0
0
1
1
0
0
SHL
x
x
x
SHL = 0: normal direction (COM0 ~ COM127)
SHL = 1: reverse direction (COM127 ~ COM0)
9.1.20 Set SEG Scan Direction
This instruction changes the relationship between the DDRAM column address and the segment driver. The SEG scan
direction can be reversed by this instruction. This feature makes IC layout more flexible for LCD module assembly.
A0
R/W
DB7
DB6
DB5
DB4
DB3
DB2
DB1
DB0
0
0
1
0
1
0
0
0
0
ADC
ADC = 0: normal direction (SEG0 ~ SEG127)
ADC = 1: reverse direction (SEG127 ~ SEG0)
9.1.21 Oscillator ON Start
This instruction enables the built-in oscillator circuit.
A0
R/W
DB7
DB6
DB5
DB4
DB3
DB2
DB1
DB0
0
0
1
0
1
0
1
0
1
1
9.1.22 & 9.1.23 Power Save
ST7571 enters Power-Save mode and reduces the power consumption to the static power consumption. It returns to the
normal operation mode by the Release Power Save Mode instruction.
Set Power Save Mode
A0
R/W
DB7
DB6
DB5
DB4
DB3
DB2
DB1
DB0
0
0
1
0
1
0
1
0
0
P
P = 0: normal mode
P = 1: power-save mode (sleep mode)
Fig. 25
Internal Procedure of Power Save
Release Power Save Mode
A0
R/W
DB7
DB6
DB5
DB4
DB3
DB2
DB1
DB0
0
0
1
1
1
0
0
0
0
1



Html Pages

1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55 56 57 58 59 60 61 62 63 64 65 66 67 68 69 70 71 72 73 74 75 76


Datasheet Download

Go To PDF Page


Link URL



Does ALLDATASHEET help your business so far?  [ DONATE ] 

About Alldatasheet   |   Advertisement   |   Contact us   |   Privacy Policy   |   Link to Datasheet    |   Link Exchange   |   Manufacturer List
All Rights Reserved©Alldatasheet.com


Mirror Sites
English : Alldatasheet.com  |   English : Alldatasheet.net  |   Chinese : Alldatasheetcn.com  |   German : Alldatasheetde.com  |   Japanese : Alldatasheet.jp
Russian : Alldatasheetru.com  |   Korean : Alldatasheet.co.kr  |   Spanish : Alldatasheet.es  |   French : Alldatasheet.fr  |   Italian : Alldatasheetit.com
Portuguese : Alldatasheetpt.com  |   Polish : Alldatasheet.pl  |   Vietnamese : Alldatasheet.vn
Indian : Alldatasheet.in  |   Mexican : Alldatasheet.com.mx  |   British : Alldatasheet.co.uk  |   New Zealand : Alldatasheet.co.nz
Family Site : ic2ic.com  |   icmetro.com