Back Button ADP5080 Datasheet HTML 15Page - Analog Devices ADP5080 Datasheet HTML 16Page - Analog Devices ADP5080 Datasheet HTML 17Page - Analog Devices ADP5080 Datasheet HTML 18Page - Analog Devices ADP5080 Datasheet HTML 19Page - Analog Devices ADP5080 Datasheet HTML 20Page - Analog Devices ADP5080 Datasheet HTML 21Page - Analog Devices ADP5080 Datasheet HTML 22Page - Analog Devices ADP5080 Datasheet HTML 23Page - Analog Devices Next Button
Zoom Inzoom in Zoom Outzoom out
 19 / 64 page
background image
Data Sheet
ADP5080
THEORY OF OPERATION
The ADP5080 is a fully integrated, high efficiency power solu-
tion for multicell lithium ion battery applications. The device
can connect directly to the battery, which eliminates the need
for preregulators and increases the battery life of the system.
The ADP5080 integrates two keep-alive LDO regulators, five
synchronous buck regulators, one configurable buck boost regu-
lator, and one high voltage LDO regulator. An integrated charge
pump provides the switch driver power supply. Along with the
integrated power FETs and drivers, integrated compensation,
soft start, and FB dividers contribute to minimize the number
of external components and the PCB layout space, providing
significant advantages for portable applications.
Factory programming sets the default values for the output
voltages, fault behavior, switching frequency, start-up time, and
other functions. These values can also be programmed via the
I2C interface. The ADP5080 features a built-in sequencer that
provides automatic startup and shutdown timing based on these
settings.
UVLO AND POR
The undervoltage lockout (UVLO) and power-on reset (POR)
functions prevent abnormal behavior and force a smooth shut-
down when input voltages fall below the minimum required
levels. The ADP5080 incorporates UVLO on VBATT, PVIN1,
and VDR12; it incorporates POR on VREG2. The thresholds
are low enough to ensure normal operation down to 4 V at
VBATT with ample hysteresis to avoid chattering.
Undervoltage Lockout (UVLO)
If the PVIN1 voltage of Channel 1 falls below the UVLO threshold
(VUVLO (F)), all channels, as well as the charge pump, are turned
off. However, LDO1 and LDO2 remain operational.
As the input voltage rises, the regulator channels do not restart
automatically. EN must be toggled after a UVLO event to restart
channels in sequencer mode or manual mode. For more informa-
tion about enabling channels using sequencer mode and manual
mode, see the Enabling and Disabling the Output Channels
section.
The VDRx pins provide the gate drive voltage to the internal
power FETs. If the VDR12 voltage falls below 2.9 V (typical),
all channels except LDO1 and LDO2 shut down to prevent
malfunction of the power FETs. As with a PVIN UVLO event,
EN must be toggled to restart channel operation.
Power-On Reset (POR)
If the VBATT voltage falls below its UVLO threshold (VUVLO(BATT)),
all channels, including LDO1 and LDO2, are shut down. This
event forces a power-on reset.
VREG2 is the voltage supply for the internal digital circuit blocks.
If the VREG2 voltage falls below the power-on reset threshold
(VUVLO (POR)) of 2.4 V typical, the ADP5080 shuts down, and all
registers are reset to their default values.
DISCHARGE SWITCH
The ADP5080 integrates discharge switches for Channel 1 to
Channel 7. These switches help to discharge the output capacitors
quickly when a channel is turned off. The discharge switches are
turned on when the EN signal goes low or when a channel is
manually turned off via I2C control, provided that the discharge
function was enabled by setting the DSCGx_ON bit (x is 1 to 7)
in Register 1. The default values for the discharge switches are
factory fuse programmed.
KEEP-ALIVE LDO REGULATORS
The keep-alive LDO linear regulators (LDO1 and LDO2) are kept
alive as long as a valid supply voltage is applied to the VBATT
pin. The LDO regulators are used to power the internal control
block of the ADP5080 so that the device is ready for the enable
(EN) signal. The outputs of LDO1 and LDO2 are also available
via the VREG1 and VREG2 pins for external circuits that are
also kept alive during system standby.
When VBATT initially rises above the UVLO threshold, LDO1
begins operation, followed by LDO2. When all UVLO thresholds
are cleared, the ADP5080 is in standby mode and ready to be
enabled. If an external voltage is used to drive VDDIO, VDDIO
can be on before VBATT; otherwise, LDO2 provides power to
VDDIO via the VREG2 output.
Rev. A | Page 19 of 64



Html Pages

1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55 56 57 58 59 60 61 62 63 64


Datasheet Download

Go To PDF Page


Link URL



Does ALLDATASHEET help your business so far?  [ DONATE ] 

About Alldatasheet   |   Advertisement   |   Contact us   |   Privacy Policy   |   Link to Datasheet    |   Link Exchange   |   Manufacturer List
All Rights Reserved©Alldatasheet.com


Mirror Sites
English : Alldatasheet.com  |   English : Alldatasheet.net  |   Chinese : Alldatasheetcn.com  |   German : Alldatasheetde.com  |   Japanese : Alldatasheet.jp
Russian : Alldatasheetru.com  |   Korean : Alldatasheet.co.kr  |   Spanish : Alldatasheet.es  |   French : Alldatasheet.fr  |   Italian : Alldatasheetit.com
Portuguese : Alldatasheetpt.com  |   Polish : Alldatasheet.pl  |   Vietnamese : Alldatasheet.vn
Indian : Alldatasheet.in  |   Mexican : Alldatasheet.com.mx  |   British : Alldatasheet.co.uk  |   New Zealand : Alldatasheet.co.nz
Family Site : ic2ic.com  |   icmetro.com