| Electronic Components Datasheet Search |
|
PMP71 Datasheet(PDF) 36 Page - Endress+Hauser Group Services AG |
|
|
|||||||||||||||||||||||||||||
PMP71 Datasheet(HTML) 36 Page - Endress+Hauser Group Services AG |
|
36 / 124 page ![]() Cerabar S PMC71, PMP71, PMP75 36 Endress+Hauser Detailed Performance Explanation and Calculation To calculate the total performance outside the –3 to +53 °C (+27 to +127 °F) temperature range or for a process isolating diaphragm material other than 1.4435/316L or Alloy C 276, please refer to the following sections: "Ambient temperature effect" and "Calculation of total performance". PMC71 standard version - Ambient temperature effect [E2] • E2 = (E2M · CF1 ) + E2E • E2M = Main temperature error • CF1 = Temperature range correction factor • E2E = Electronics error for analog current output E2M - Main temperature error The output changes due to the effect of ambient temperature [IEC 61298-3] with respect to reference temperature [DIN 16086]. The values specify the maximum error due to min./max. ambient or process temperature conditions. Ambient temperature effect per 28 °C 1) (per 50 °F) Measuring cell Standard Gauge pressure and absolute pressure Platinum Gauge pressure and absolute pressure 100 mbar (1.5 psi) ± (0.07 · TD + 0.038) ± (0.07 · TD + 0.038) 250 mbar (3.75 psi) ± (0.07 · TD + 0.038) ± (0.07 · TD + 0.038) 400 mbar (6 psi) ± (0.07 · TD + 0.038) ± (0.07 · TD + 0.038) 1 bar (15 psi) ± (0.065 · TD + 0.02) ± (0.065 · TD + 0.02) 2 bar (30 psi) ± (0.065 · TD + 0.02) ± (0.065 · TD + 0.02) 4 bar (60 psi) ± (0.065 · TD + 0.02) ± (0.065 · TD + 0.02) 10 bar (150 psi) ± (0.065 · TD + 0.02) ± (0.065 · TD + 0.02) 40 bar (600 psi) ± (0.065 · TD + 0.02) ± (0.065 · TD + 0.02) 1) Valid for the temperature range 25 °C ± per 28 °C (77 °F ± per 50 °F) CF1 - Temperature range correction factor Measuring cell Temperature range Factor, CF1 100 mbar (1.5 psi) 250 mbar (3.75 psi) 400 mbar (6 psi) 1 bar (15 psi) 2 bar (30 psi) 4 bar (60 psi) 10 bar (150 psi) 40 bar (600 psi) 25°C ± per 28°C (77°F ± per 50°F) 1 –20 to –4 °C (–4 to +25 °F) and +54 to +82 °C (+129 to +180 °F) 2.4 +83 to +125 °C (+181 to +257 °F) 2.4 E2E - Electronics error Measuring cell Electronics Error (%) For all measuring cells Digital output (HART/PA/FF) 0.05 % Analog output (4 to 20 mA/1 to 5V) 0.05 % |
|
Link URL |
| Does ALLDATASHEET help your business so far? [ DONATE ] |
About Alldatasheet | Advertisement | Contact us | Privacy Policy | Link to Datasheet | Link Exchange | Manufacturer List All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |