| Electronic Components Datasheet Search |
|
PMP71 Datasheet(PDF) 20 Page - Endress+Hauser Group Services AG |
|
|
|||||||||||||||||||||||||||||
PMP71 Datasheet(HTML) 20 Page - Endress+Hauser Group Services AG |
|
20 / 124 page ![]() Cerabar S PMC71, PMP71, PMP75 20 Endress+Hauser Profile version 3.0 • SW version 03.00.zz • SW version 04.00.zz 3.02 SW version 04.01.zz ( device revision 3) Compatibility with SW version 03.00.zz and higher. GSD revision • 4 (SW version 3.00.zz and 4.00.zz) • 5 (device revision 3) DD revision • 1 (SW version 3.00.zz and 4.00.zz) • 1 (device revision 3) GSD file Information and files at: • www.endress.com • www.profibus.org DD files Output values Measured value for PV (via Analog Input Function Block) • Pressure • Level • Tank content Measured value for SV • Pressure • Temperature Input values Input value sent from PLC, can be shown on display Supported functions • Identification & maintenance Simplest device identifier on the control system and nameplate • Condensed status (only with Profile Version 3.02) • Automatic ID number adjustment and switchable to the following ID numbers (only with Profile Version 3.02): – 9700: Profile-specific transmitter identification number with the "Classic" or "Condensed" status". – 1501: Compatibility mode for the old Cerabar S generation (PMC731, PMP731, PMC631, PMP635). – 1541: Identification number for the new Cerabar S generation (PMC71, PMP71, PMP75). • Device locking: The device can be locked by hardware or software. FOUNDATION Fieldbus protocol-specific data Manufacturer ID 452B48 hex Device type 1007 hex Device revision • 6 - SW version 03.00.zz • 7 - SW version 04.00.zz (FF-912) DD revision • 3 (device revision 6) • 2 (device revision 7) CFF revision • 4 (device revision 6) • 1 (device revision 7) DD files Information and files at: • www.endress.com • www.fieldbus.org CFF files Device tester version (ITK version) • 5.0 (device revision 6) • 6.01 (device revision 7) Number of ITK test campaign • IT054600 (Device Revision 6) • IT085500 (Device Revision 7) Link Master (LAS) capable Yes Choice of "Link Master" and "Basic Device" Yes, factory setting is Basic Device Node address Factory setting: 247 (F7 hex) |
|
Link URL |
| Does ALLDATASHEET help your business so far? [ DONATE ] |
About Alldatasheet | Advertisement | Contact us | Privacy Policy | Link to Datasheet | Link Exchange | Manufacturer List All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |