| Electronic Components Datasheet Search |
|
PMP71 Datasheet(PDF) 38 Page - Endress+Hauser Group Services AG |
|
|
|||||||||||||||||||||||||||||
PMP71 Datasheet(HTML) 38 Page - Endress+Hauser Group Services AG |
|
38 / 124 page ![]() Cerabar S PMC71, PMP71, PMP75 38 Endress+Hauser Total error Total error = total performance + long-term stability Total performance in % of the set span with TD1:1 → 35 Long-term stability in % of the upper range limit (URL) → 35 Measuring cell Gauge pressure - Standard 1) Gauge pressure - platinum 1) PMC71 - % of the upper range limit / PMC71 - % of the upper range limit / 1 year 5 years 10 years 1 year 5 years 10 years 100 mbar (1.5 psi) ± 0.225 ± 0.255 ± 0.275 ± 0.216 ± 0.246 ± 0.266 250 mbar (3.75 psi) ± 0.225 ± 0.255 ± 0.275 ± 0.216 ± 0.246 ± 0.266 400 mbar (6 psi) ± 0.216 ± 0.246 ± 0.266 ± 0.212 ± 0.242 ± 0.262 1 bar (15 psi) ± 0.194 ± 0.224 ± 0.244 ± 0.189 ± 0.219 ± 0.239 2 bar (30 psi) ± 0.194 ± 0.224 ± 0.244 ± 0.187 ± 0.217 ± 0.237 4 bar (60 psi) ± 0.194 ± 0.224 ± 0.244 ± 0.187 ± 0.217 ± 0.237 10 bar (150 psi) ± 0.194 ± 0.224 ± 0.244 ± 0.187 ± 0.217 ± 0.237 40 bar (600 psi) ± 0.194 ± 0.224 ± 0.244 ± 0.187 ± 0.217 ± 0.237 1) The specification values are applicable to the temperature range per 28 °C (per 50 °F) with reference to + 25°C (77°F) for all measuring cells. The specification values are applicable to analog output (i.e. inclusion of electronics error). Measuring cell Absolute pressure - Standard 1) Absolute pressure - Platinum PMC71 - % of the upper range limit / PMC71 - % of the upper range limit / 1 year 5 years 10 years 1 year 5 years 10 years 100 mbar (1.5 psi) ± 0.225 ± 0.325 ± 0.375 ± 0.216 ± 0.316 ± 0.366 250 mbar (3.75 psi) ± 0.225 ± 0.325 ± 0.375 ± 0.216 ± 0.316 ± 0.366 400 mbar (6 psi) ± 0.216 ± 0.316 ± 0.366 ± 0.212 ± 0.312 ± 0.362 1 bar (15 psi) ± 0.194 ± 0.294 ± 0.344 ± 0.189 ± 0.289 ± 0.339 2 bar (30 psi) ± 0.194 ± 0.294 ± 0.344 ± 0.187 ± 0.287 ± 0.337 4 bar (60 psi) ± 0.194 ± 0.294 ± 0.344 ± 0.187 ± 0.287 ± 0.337 10 bar (150 psi) ± 0.194 ± 0.294 ± 0.344 ± 0.187 ± 0.287 ± 0.337 40 bar (600 psi) ± 0.194 ± 0.294 ± 0.344 ± 0.187 ± 0.287 ± 0.337 1) The specification values are applicable to the temperature range per 28 °C (per 50 °F) with reference to + 25°C (77°F) for all measuring cells. The specification values are applicable to analog output (i.e. inclusion of electronics error). |
|
Link URL |
| Does ALLDATASHEET help your business so far? [ DONATE ] |
About Alldatasheet | Advertisement | Contact us | Privacy Policy | Link to Datasheet | Link Exchange | Manufacturer List All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |