18 / 124 page ![]() Cerabar S PMC71, PMP71, PMP75 18 Endress+Hauser Type Measuring cell Dead time (t1) [ms] Dead time (t1) [ms] + Time constant T63 (t2) [ms] Dead time (t1) [ms] + Time constant T90 (t3) [ms] PMP71 Min. • 400 mbar (6 psi) • ≥1 bar (15 psi) 80 • 150 • 115 • 196 • 116 max. • 400 mbar (6 psi) • ≥1 bar (15 psi) 1280 • 1350 • 1315 • 1396 • 1316 PMP75 max. PMP71 + influence of the diaphragm seal Reading cycle (PLC) • Acyclic: Typically 25/s • Cyclic: Typically 30/s (depending on the number and type of the function blocks used in the closed-control loop) Cycle time (update time) Min. 200 ms The cycle time in a bus segment in cyclic data communication depends on the number of devices, on the segment coupler used and on the internal PLC cycle time. A new measured value can be determined up to five times a second. Response time • Acyclic: Approx. 60 ms to 70 ms (depending on Min. Slave Interval) • Cyclic: Approx. 10 ms to 13 ms (depending on Min. Slave Interval) Dynamic behavior FOUNDATION Fieldbus A typical configuration for the macro cycle time (host system) of 1 s results in the following behavior: Type Measuring cell Dead time (t1) [ms] Dead time (t1) [ms] + Time constant T63 (t2) [ms] Dead time (t1) [ms] + Time constant T90 (t3) [ms] PMC71 Min. All 135 255 321 max. 1135 1255 1321 PMP71 Min. • 400 mbar (6 psi) • ≥1 bar (15 psi) 90 • 160 • 125 • 206 • 126 max. • 400 mbar (6 psi) • ≥1 bar (15 psi) 1090 • 1160 • 1125 • 1206 • 1126 PMP75 max. PMP71 + influence of the diaphragm seal Reading cycle • Acyclic: Typically 10/s • Cyclic: max. 10/s (dependent on the number and type of function blocks used in a closed-control loop) Cycle time (update time) Cyclic: Min. 100 ms Response time • Acyclic: Typically 100 ms (for standard bus parameter settings) • Cyclic: max. 20 ms (for standard bus parameter settings) Damping A damping affects all outputs (output signal, display): • Via onsite display, handheld terminal or PC with operating program, continuous from 0 to 999 s • Also for HART and PROFIBUS PA: Via DIP switch on the electronic insert, switch position "on" = set value and "off" • Factory setting: 2 s |
|
Link URL |
| Does ALLDATASHEET help your business so far? [ DONATE ] |
About Alldatasheet | Advertisement | Contact us | Privacy Policy | Link to Datasheet | Link Exchange | Manufacturer List All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |