102 / 109 page ![]() Common to F3SG-SR and F3SG-PG 102 Muting Sequence Error Indication The following table is applied only when the muting function is being enabled. * Factory default setting Interlock Sequence Error Indication The following table is applied only when the pre-reset function is being enabled. SEQ indicator Cause and measures Blinking: Once Power supply may have been turned ON with muting input A or B being ON. Check the condition of the muting sensors and the F3SG-SR/PG. Muting input B may have been turned ON before muting input A was turned ON. Check the condition of the muting sensors. Muting input A and B may have been turned ON at the same time. • Check the arrangement of the muting sensors. • Check if the wiring of muting input A and B is short-circuited. Either muting input A or B may have been turned ON with the F3SG-SR/PG being blocked or INTERLOCK State. Check the condition of the F3SG-SR/PG. Blinking: Twice Muting input B may have been turned ON within T1min (= 0.1 s *) after muting input A was turned ON. • Check that if the muting sensors are installed too close each other. • Check that if the speed of the workpiece is too fast. It may have taken T1max (= 4 s *) or longer for muting input B to be turned ON after muting input A was turned ON. • Check that if the muting sensors are installed too far each other. • Check that if the speed of the workpiece is too slow. The F3SG-SR/PG may have been blocked after muting input A was turned ON but before muting input B was turned ON. Check the condition of the F3SG-SR/PG. Blinking: Four times The F3SG-SR/PG may have been blocked within 0.08 s after muting input A and B were normally turned ON. • Check that if the muting sensor and the F3SG-SR/PG are installed too close each other. • Check that if the speed of the workpiece is too fast. Muting may have been released after the F3SG-SR/PG entered the MUTING state but before a workpiece blocked the F3SG-SR/PG. • Check that the workpiece still remains. • Check that the speed of the workpiece is too slow. Blinking: Five times The F3SG-SR/PG entered the MUTING state, but muting may have then been released while a workpiece passes through the F3SG-SR/PG. • Check that the workpiece still remains. • Check that if the speed of the workpiece is too slow. • Check that the muting sensors have been installed upstream and downstream of the F3SG-SR/PG with the size of workpieces taken into account. (Using four muting sensors) Blinking: Six times Muting may have been released with muting input A and B remained ON after a workpiece passed through the F3SG-SR/PG. • Check that the workpiece still remains. • Check that the speed of the workpiece is too slow. Blinking: Seven times The next muting sequence may have started after muting was released but before the initial muting condition was established. • Check that if a next workpiece has not entered before the current workpiece passes through the F3SG-SR/ PG. • Check that if the interval between workpieces are too narrow. SEQ indicator Cause and measures Blinking: Once The reset or pre-reset switch may have been pressed before the F3SG-SR/PG receives light. Check the wiring of the reset and pre-reset signals. The F3SG-SR/PG may have been blocked or the pre-reset switch may have been pressed before the pre-reset switch is pressed. Check the status of the F3SG-SR/PG and the wiring of the pre-reset signal. Blinking: Twice After the pre-reset switch was pressed, the pre-reset or reset switch may have been pressed before the F3SG- SR/PG is blocked. Check the installation environment of the F3SG-SR/PG. Blinking: Three times After the pre-reset switch was pressed and the F3SG-SR/PG was blocked, the pre-reset switch may have been pressed before the reset switch is pressed. Check the wiring of the pre-reset signal. After the pre-reset switch was pressed, a time period from the block of the F3SG-SR/PG to the press of the reset switch may have exceeded the allowable time. Check the installation environment of the F3SG-SR/PG as well as pre-reset and reset switches. The number of blocks of the F3SG-SR/PG may have exceeded the allowable value after the pre-reset switch was pressed and before the reset switch is pressed. Check the installation environment of the F3SG-SR/PG. |
|
Link URL |
| Does ALLDATASHEET help your business so far? [ DONATE ] |
About Alldatasheet | Advertisement | Contact us | Privacy Policy | Link to Datasheet | Link Exchange | Manufacturer List All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |