103 / 109 page ![]() Common to F3SG-SR and F3SG-PG 103 PSDI Sequence Error Indication The following table is applied only when the PSDI function is being enabled. Notations ...Single Break ...Double Break ...Common SEQ indicator Error condition Cause and measures Blinking: Once Power supply may have been turned ON with PSDI input being OFF. Check the condition of the light curtains and PSDI input wiring. Power supply may have been turned ON with the light curtain blocked. Check the condition of the light curtains and PSDI input wiring. Power supply may have been turned ON with RESET input being OFF. Check the condition of the light curtains and RESET input wiring. PSDI input may have been turned OFF before RESET input was turned OFF. Check the PSDI input wiring. The light curtain may have been blocked before RESET input was turned ON. Check the condition of the light curtains and RESET input wiring. The PSDI input may have turned OFF while the RESET input is OFF. Check the condition of the light curtains and PSDI input wiring. The light curtain may have been blocked before RESET input was turned ON. Check the condition of the light curtains and RESET input wiring. Blinking: Twice After RESET input , the light curtain may not be blocked longer than T2 and the PSDI input may have turned OFF. Check the condition of the light curtains and RESET input wiring. The PSDI input may have turned OFF with the light curtain blocked. Check the condition of the light curtains and PSDI input wiring. PSDI input may have turned OFF before the light curtain blocked twice. Check the condition of the light curtains and PSDI input wiring. Blinking: Three times The light curtain was blocked before the PSDI input turned OFF. Check the condition of the light curtains and PSDI input wiring. The light curtain was blocked while the PSDI input turned OFF. Check the condition of the light curtains and PSDI input wiring. Blinking: Four times PSDI input may have turned OFF during the period from when the PSDI state is canceled until the light curtain blocked. Check the condition of the light curtains and PSDI input wiring. The PSDI input may have turned OFF with the light curtain blocked. Check the condition of the light curtains and PSDI input wiring. It may have taken T4 (= 30 s) or longer for PSDI input to be turned OFF after the light curtain blocked. Check the condition of the light curtains and PSDI input wiring. It may have taken T6 (= 30 s) or longer for PSDI input to be turned OFF after the light curtain blocked. Check the condition of the light curtains and PSDI input wiring. The PSDI input may have turned OFF again before the light curtain blocked. Check the condition of the light curtains and PSDI input wiring. It may have taken T6 (= 30 s) or longer for PSDI input to be turned OFF after the light curtain blocked twice. Check the condition of the light curtains and PSDI input wiring. PSDI input may have turned OFF before the light curtain blocked again. Check the light curtain status and PSDI input wiring. |
|
Link URL |
| Does ALLDATASHEET help your business so far? [ DONATE ] |
About Alldatasheet | Advertisement | Contact us | Privacy Policy | Link to Datasheet | Link Exchange | Manufacturer List All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |