161 / 560 page ![]() Section 8 Multifunction Timer Pulse Unit (MTU) Rev.1.00 Sep. 18, 2008 Page 127 of 522 REJ09B0069-0100 Table 8.9 MD0 to MD3 Bit 3 MD3 Bit 2 MD2 Bit 1 MD1 Bit 0 MD0 Description 0 0 0 0 Normal operation 1 Reserved (setting prohibited) 1 0 PWM mode 1 1 PWM mode 2* 1 1 0 0 Phase counting mode 1* 2 1 Phase counting mode 2* 2 1 0 Phase counting mode 3* 2 1 Phase counting mode 4* 2 1 0 0 0 Reset synchronous PWM mode* 3 1 Reserved (setting prohibited) 1 x Reserved (setting prohibited) 1 0 0 Reserved (setting prohibited) 1 Complementary PWM mode 1 (transmit at peak)* 3 1 0 Complementary PWM mode 2 (transmit at trough)* 3 1 Complementary PWM mode 2 (transmit at peak and trough)* 3 Legend: x: Don’t care Notes: 1. PWM mode 2 can not be set for channels 3 and 4. 2. Phase counting mode can not be set for channels 0, 3, and 4. 3. Reset synchronous PWM mode, complementary PWM mode can only be set for channel 3. When channel 3 is set to reset synchronous PWM mode or complementary PWM mode, the channel 4 settings become ineffective and automatically conform to the channel 3 settings. However, do not set channel 4 to reset synchronous PWM mode or complementary PWM mode. Reset synchronous PWM mode and complementary PWM mode can not be set for channels 0, 1, and 2. 8.3.3 Timer I/O Control Register (TIOR) The TIOR registers are 8-bit readable/writable registers that control the TGR registers. The MTU has eight TIOR registers, two each for channels 0, 3, and 4, and one each for channels 1 and 2. Care is required as TIOR is affected by the TMDR setting. The initial output specified by TIOR is valid when the counter is stopped (the CST bit in TSTR is cleared to 0). Note also that, in PWM mode 2, the output at the point at which the counter is cleared to 0 is specified. When TGRC or TGRD is designated for buffer operation, this setting is invalid and the register operates as a buffer register. |
|
Link URL |
| Does ALLDATASHEET help your business so far? [ DONATE ] |
About Alldatasheet | Advertisement | Contact us | Privacy Policy | Link to Datasheet | Link Exchange | Manufacturer List All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |