| Electronic Components Datasheet Search |
|
TLE8718SA Datasheet(PDF) 69 Page - Infineon Technologies AG |
|
|
|||||||||||||||||||||||||||||
TLE8718SA Datasheet(HTML) 69 Page - Infineon Technologies AG |
|
69 / 82 page ![]() TLE 8718 SA Control of the device Data Sheet 69 Rev. 1.1, 2012-07-31 12.2.5 OUT1516 Table 37 CONREG4, DELAYIN configuration Configuration of tDELAYIN_x delay DELAYIN_CONF1 DELAYIN_CONF0 Description 1 1 Long delay t DELAYIN_L, see Item 7.0.16 0 1 Medium long delay t DELAYIN_ML, see Item 7.0.17 1 0 Medium short delay t DELAYIN_MS, see Item 7.0.18 0 0 Short delay t DELAYIN_S, see Item 7.0.19 Table 38 CONREG4, Upstream divider configuration1) 1) Take care that Item 11.5.38 fSDO is not exceeded. Configuration of upstream clock divider FCL_CONF1 FCL_CONF0 Description 1 0 Upstream clock is f FCL/128 0 1 Upstream clock is f FCL/64 0 0 Upstream clock is f FCL/32 1 1 Upstream clock is f FCL/16 Table 39 OUT1516 Reset sources: RST, power-on-reset, ABE, over-/undervoltage, OUT1516 timeout 1), MSC_MON, RES15_16 1) Timeout tdelres only resets the register if another failure (RST, ABE, over-/undervoltage, MSC-timeout) is still present. POR and the filtered RES15_16 resets the register immediately. Controller read access: RD_CONFIG = ’1 00001 xxx1 xxxx xxx’ Controller write access: WR_ OUT1516 = ’1 11100 CD0...CD7 xxx’ UD/CD Name Description Reset value 0 OUT15_CONTROL See table “Output stage switching” below 12) 2) After POR has occurred or RES15_16 is released OUT15, OUT16 starts in OFF- state. OUTn_DELAY, OUTn_CONTROL reset Values remain =’1’ 1 OUT15_DELAY See table “Output stage switching” below 12) 2 OUT15_DIAC ‘1‘:OUT15 diagnostic pull-down current and Open Load OL on ‘0‘:OUT15 diagnostic pull-down current and Open Load OL off 0 3 OUT15_ SCB ‘1‘: OUT15 is switched off in case of SCB ‘0‘: OUT15 current limited mode in case of SCB 1 4 OUT16_CONTROL See table “Output stage switching” below 12) 5 OUT16_DELAY See table “Output stage switching” below 12) 6 OUT16_DIAC ‘1‘:OUT16 diagnostic pull-down current and Open Load OL on ‘0‘:OUT16 diagnostic pull-down current and Open Load OL off 0 7 OUT16_ SCB ‘1‘: OUT16 is switched off in case of SCB ‘0‘: OUT16 current limited mode in case of SCB 1 |
|
Link URL |
| Does ALLDATASHEET help your business so far? [ DONATE ] |
About Alldatasheet | Advertisement | Contact us | Privacy Policy | Link to Datasheet | Link Exchange | Manufacturer List All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |