Back Button PMP71 Datasheet HTML 107Page - Endress+Hauser Group Services AG PMP71 Datasheet HTML 108Page - Endress+Hauser Group Services AG PMP71 Datasheet HTML 109Page - Endress+Hauser Group Services AG PMP71 Datasheet HTML 110Page - Endress+Hauser Group Services AG PMP71 Datasheet HTML 111Page - Endress+Hauser Group Services AG PMP71 Datasheet HTML 112Page - Endress+Hauser Group Services AG PMP71 Datasheet HTML 113Page - Endress+Hauser Group Services AG PMP71 Datasheet HTML 114Page - Endress+Hauser Group Services AG PMP71 Datasheet HTML 115Page - Endress+Hauser Group Services AG Next Button
Zoom Inzoom in Zoom Outzoom out
 111 / 124 page
background image
Cerabar S PMC71, PMP71, PMP75
Endress+Hauser
111
Mounting with temperature isolator
Endress+Hauser recommends the use of temperature isolators in the event of constant extreme fluid
temperatures which cause the maximum permitted electronics temperature of +85 °C (+185 °F) to be
exceeded.
Diaphragm seal systems with temperature isolators can be used with maximum temperatures up to
+400 °C (+752 °F) depending on the filling oil used →  111, see the "Diaphragm seal filling oils"
section.
To minimize the influence of rising heat, Endress+Hauser recommends the device be mounted
horizontally or with the housing pointing downwards. The additional installation height also brings
about a zero point shift of maximum 21 mbar (0.315 psi) due to the hydrostatic column in the
temperature isolator. You can correct this zero point shift at the device.
The temperature restrictions are at their lowest with an insulation height of 30 mm (1.18 in).
Complete insulation behaves in practically the same way as no insulation!
The graphic below illustrates the temperature limits with an insulation height of 30 mm (1.18 in):
Tp
T
a
+212
+176
+140
+104
+68
+32
-4
-40
-76
+400
+350
+300
+250
+200
+150
+100
+50
0
-50
-100
+752
+662
+572
+482
+392
+302
+212
+122
+32
-58
-148
[°C]
[°F]
[°C]
[°F]
+100
+80
+60
+40
+20
0
-20
-40
-60
A
B
1
2
A
D
E
F
G
C
B
A0031354
A
Ambient temperature: ≤ 85 °C (185 °F)
B
Process temperature: max. 400 °C (752 °F), depends on the diaphragm seal filling oil used
C
Device with temperature isolator, material 316L (1.4404)
D
No insulation
E
Maximum insulation
F
30 mm (1.18 in)Insulation
G
No insulation, maximum insulation, 30 mm (1.18 in) insulation
1
Insulation height30 mm (1.18 in)
2
Insulation material



Html Pages

1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55 56 57 58 59 60 61 62 63 64 65 66 67 68 69 70 71 72 73 74 75 76 77 78 79 80 81 82 83 84 85 86 87 88 89 90 91 92 93 94 95 96 97 98 99 100  ...More


Datasheet Download

Go To PDF Page


Link URL



Does ALLDATASHEET help your business so far?  [ DONATE ] 

About Alldatasheet   |   Advertisement   |   Contact us   |   Privacy Policy   |   Link to Datasheet    |   Link Exchange   |   Manufacturer List
All Rights Reserved©Alldatasheet.com


Mirror Sites
English : Alldatasheet.com  |   English : Alldatasheet.net  |   Chinese : Alldatasheetcn.com  |   German : Alldatasheetde.com  |   Japanese : Alldatasheet.jp
Russian : Alldatasheetru.com  |   Korean : Alldatasheet.co.kr  |   Spanish : Alldatasheet.es  |   French : Alldatasheet.fr  |   Italian : Alldatasheetit.com
Portuguese : Alldatasheetpt.com  |   Polish : Alldatasheet.pl  |   Vietnamese : Alldatasheet.vn
Indian : Alldatasheet.in  |   Mexican : Alldatasheet.com.mx  |   British : Alldatasheet.co.uk  |   New Zealand : Alldatasheet.co.nz
Family Site : ic2ic.com  |   icmetro.com