65 / 430 page ![]() PM7375 LASAR-155 DATA SHEET PMC-931127 ISSUE 6 LOCAL ATM SAR & PHYSICAL LAYER PROPRIETARY AND CONFIDENTIAL TO PMC-SIERRA, INC., AND FOR ITS CUSTOMERS’ INTERNAL USE 49 Cell copying is only supported if the LASAR-155's receive Multipurpose Port is enabled to source cells using input RXPHYBP. If enabled as a cell source, cell copying to the Multipurpose Port can be based on the VPI/VCI code and/or PTI codepoints. 9.4.2 AAL Layer Processing AAL Layer processing includes Common Part Convergence Sublayer AAL Type 5 Protocol Data Unit (CPAAL5_PDU) reassembly and verification. In addition, a mechanism for smooth reassembly startup and smooth reassembly shutdown is provided. The RALP performs CPAAL5_PDU reassembly by associating cells with the same VPI/VCI code with a CPAAL5_PDU. The normal indication of the end of a CPAAL5_PDU is provided using a PTI codepoint while the start of a CPAAL5_PDU is implicit based on the previous CPAAL5_PDU end indication. When a VC is first provisioned for reception and a cell for the VC arrives, the RALP starts to reassemble a CPAAL5_PDU. As additional cells of a CPAAL5_PDU are received, the RALP continues to accumulate cells for a given CPAAL5_PDU until the CPAAL5_PDU is terminated either normally or abnormally through an exception. Reassembly is facilitated using the PCI DMA Controller (PCID) block. Normal termination of a CPAAL5_PDU results from the reception of a cell with the appropriate PTI codepoint and valid CPAAL5_PDU Length, Control and CRC-32 fields. The CRC-32 polynomial used is: x32+x26+x23+x22+x16+x12+x11+x10+x8+x7+x5+x4+x2+x+1. Abnormal termination of a CPAAL5_PDU can result from either CPAAL5_PDU length exceptions, Control field exceptions or CRC-32 exceptions. Length exceptions can result from either the receive CPAAL5_PDU LENGTH field not matching the received number of CPAAL5_SDU octets, the receive CPAAL5_PDU LENGTH field equal to zero (indicating a forward abort) or the received CPAAL5_PDU exceeding the maximum CPAAL5_PDU size. If the current CPAAL5_PDU under reassembly exceeds the maximum CPAAL5_PDU size, the CPAAL5_PDU is terminated and all additional cells received are dropped until the last cell of the CPAAL5_PDU is received. The maximum CPAAL5_PDU size can be user programmed. Control field exceptions result when the received CPAAL5_PDU CPI field is non zero. A CRC-32 exception results when the calculated CRC-32 over the received CPAAL5_PDU does not produce the expected residue. The RALP block also provides smooth reassembly shut down. Through user control, the RALP can be configured to either stop reassembly on all VCs immediately or after the active CPAAL5_PDU has been reassembled. |
|
Link URL |
| Does ALLDATASHEET help your business so far? [ DONATE ] |
About Alldatasheet | Advertisement | Contact us | Privacy Policy | Link to Datasheet | Link Exchange | Manufacturer List All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |