Back Button SI3233 Datasheet HTML 51Page - Silicon Laboratories SI3233 Datasheet HTML 52Page - Silicon Laboratories SI3233 Datasheet HTML 53Page - Silicon Laboratories SI3233 Datasheet HTML 54Page - Silicon Laboratories SI3233 Datasheet HTML 55Page - Silicon Laboratories SI3233 Datasheet HTML 56Page - Silicon Laboratories SI3233 Datasheet HTML 57Page - Silicon Laboratories SI3233 Datasheet HTML 58Page - Silicon Laboratories SI3233 Datasheet HTML 59Page - Silicon Laboratories Next Button
Zoom Inzoom in Zoom Outzoom out
 55 / 100 page
background image
Si3233
Preliminary Rev. 0.5
55
Reset settings = 0000_0000
Register 32. Oscillator 1 Control
Bit
D7D6D5D4D3D2
D1
D0
Name
OSS1
REL
OZ1
O1TAE
O1TIE
O1E
O1SO[1:0]
Type
R
R/W
R/W
R/W
R/W
R/W
R/W
Bit
Name
Function
7
OSS1
Oscillator 1 Signal Status.
0 = Output signal inactive.
1 = Output signal active.
6REL
Oscillator 1 Automatic Register Reload.
This bit should be set for FSK signaling.
0 = Oscillator 1 will stop signaling after inactive timer expires.
1 = Oscillator 1 will continue to read register parameters and output signals.
5OZ1
Oscillator 1 Zero Cross Enable.
0 = Signal terminates after active timer expires.
1 = Signal terminates at zero crossing after active timer expires.
4O1TAE
Oscillator 1 Active Timer Enable.
0 = Disable timer.
1 = Enable timer.
3O1TIE
Oscillator 1 Inactive Timer Enable.
0 = Disable timer.
1 = Enable timer.
2O1E
Oscillator 1 Enable.
0 = Disable oscillator.
1 = Enable oscillator.
1:0
O1SO[1:0]
Oscillator 1 Signal Output Routing.
00 = Unassigned path (output not connected).
01 = Assign to transmit path.
10 = Assign to receive path.
11 = Assign to both paths.



Html Pages

1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55 56 57 58 59 60 61 62 63 64 65 66 67 68 69 70 71 72 73 74 75 76 77 78 79 80 81 82 83 84 85 86 87 88 89 90 91 92 93 94 95 96 97 98 99 100


Datasheet Download

Go To PDF Page


Link URL



Does ALLDATASHEET help your business so far?  [ DONATE ] 

About Alldatasheet   |   Advertisement   |   Contact us   |   Privacy Policy   |   Link to Datasheet    |   Link Exchange   |   Manufacturer List
All Rights Reserved©Alldatasheet.com


Mirror Sites
English : Alldatasheet.com  |   English : Alldatasheet.net  |   Chinese : Alldatasheetcn.com  |   German : Alldatasheetde.com  |   Japanese : Alldatasheet.jp
Russian : Alldatasheetru.com  |   Korean : Alldatasheet.co.kr  |   Spanish : Alldatasheet.es  |   French : Alldatasheet.fr  |   Italian : Alldatasheetit.com
Portuguese : Alldatasheetpt.com  |   Polish : Alldatasheet.pl  |   Vietnamese : Alldatasheet.vn
Indian : Alldatasheet.in  |   Mexican : Alldatasheet.com.mx  |   British : Alldatasheet.co.uk  |   New Zealand : Alldatasheet.co.nz
Family Site : ic2ic.com  |   icmetro.com