34 / 110 page ![]() LTC3888-1 34 Rev. 0 For more information www.analog.com OPERATION FACTORY DEFAULT OPERATION The LTC3888-1 ships from the factory with a default con- figuration stored in its non-volatile memory unless custom programming has been requested. These command values are loaded into volatile RAM when the chip is initialized. Prior to receiving any PMBus commands, a stock LTC3888-1 will operate in the factory default mode. If a STORE_USER_ ALL command is executed, the contents of the non-volatile memory are replaced with active command values from internal RAM, and that will permanently overwrite the fac- tory defaults. Table 5 summarizes the default factory opera- tion settings of the LTC3888-1 if all resistor configuration pins are left open. These defaults allow parameters listed in bold text in the table to be overridden with configuration resistor programming. Warning limits are given in Table 5 because exceeding them will cause the ALERT pin to be asserted even if the PMBus interface is not being utilized. Table 5. Factory Default Operation Summary PARAMETER* DEFAULT SETTING UNITS PMBus Address All writes enabled to Channel 0 at address 0x4F (no PEC). – Operation OPERATION enabled with RUN pin control and soft-off. – Input Voltage OFF Threshold 6.0 V Input Voltage UV Warning Limit 6.3 V Input Voltage ON Threshold 6.5 V Input Voltage OV Fault Limit 15.5 V Input Voltage OV Fault Response Latch off – Soft-Start Time 1.6 (with no delay) ms Maximum Start-Up Time (TMAX) 10 ms TMAX Fault Response Retry every 350ms – Output Voltage UV Fault Limit –10% of nominal VOUT – Output Voltage UV Fault Response Retry every 350ms – Output Voltage Set by external R-divider (VFB = 400mV, VOUT servo disabled) – Output Voltage OV Fault Limit 10% of nominal VOUT – Output Voltage OV Fault Response Latch off – Shut Down 1.6ms soft-off – Output Current Monitor Gain 5.0 mΩ Output Current OC Warning/Fault Limits 20/29.75 A Output Current OC Fault Response Ignore – PWM Switching Frequency 500 kHz Master/Slave Configuration 4+4 (or 8-phase) – Internal Overtemperature Warning/Fault Limits 130/160 °C Internal Overtemperature Responses Warning: EEPROM disabled; Fault: PWM disabled – External Overtemperature Warning/Fault Limits 85/100 °C External Overtemperature Fault Response Retry every 350ms – FAULT Asserts low for the following faults: VOUT UV or OV, VIN OV, external or internal OT, TON_MAX, or output short cycle – ALERT Masking Masked for loss of PLL lock and external fault inputs – *Bold entries can be changed with external configuration resistors |
|
Link URL |
| Does ALLDATASHEET help your business so far? [ DONATE ] |
About Alldatasheet | Advertisement | Contact us | Privacy Policy | Link to Datasheet | Link Exchange | Manufacturer List All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |